10. Event
10.1 Event > Alarm Port
Alarm Input
- Used for connecting external alarm devices and triggering images for
specific alarm-based events. The input is typically connected to a motion
detector or any other external security device, and images could be
uploaded whenever the detector is activated.
Maximum 5VDC
is allowed
on the input.
Output
- This could drive a maximum load of
0.5A 125VAC / 1A 30VDC
directly or
heavier loads by connecting additional relay circuitry. If the output is used
with an external relay, a diode must be connected in parallel with the load for
protection against any voltage transients.
Duration -
This parameter sets the minimum tampering period, that is, an alarm will not
be triggered until this period has lapsed, even if the tampering conditions are
otherwise met. This could help to prevent false alarms for known conditions
that affect the image.
Caution!
Connecting AC to the inputs/outputs will damage the unit.