![Ganz CTR-024N-2 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/ganz/ctr-024n-2/ctr-024n-2_instruction-manual_3425098016.webp)
(10/2000)
16
Power Cuts
The video recorder detects power cuts and logs
each incident along with the corresponding date and
time, showing you when each power failure began
and ended. P.FAIL on the display indicates that a
power cut has occurred while the video recorder
was active.
Note
Power cuts with a duration of under one
second are not registered. Automatic
restart of the recording function is no longer
possible if the power cut in question lasts
longer than five minutes.
You can display a list of the last eight power cuts,
with the data shown in chronological order.
- Stop the machine if it is still recording.
- Open the flap on the front of the unit and press
the MENU button. This will display the main
menu.
- Press the DOWN button repeatedly until POWER
FAIL INFORM is marked, then press the ENTER
button. This will display a list of detected power
failures.
- Press the DOWN button repeatedly once more if
you wish to display any further entries.
- Press the CLEAR button to delete the marked
entry.
- Finally, press the MENU button repeatedly until
the menu disappears from the display.
Text display position adjustment
Depending on the type of programming, the monitor
will display the date, time and tape running time.
You can displace these text displays for the purpose
- for example - of making certain areas of the screen
easier to see.
- Open the flap on the front of the recorder.
- Press the V-POS and H-POS buttons repeatedly
until the texts begin to move. Position and order
the texts as required.
Operation
POWER FAIL RECALL
1 OFF 03/29/00 15:42:05
ON 03/29/00 17:32:19
2 OFF 05/10/00 23:57:05
ON 05/11/00 00:32:19
3 OFF --/--/-- --:--:--
ON --/--/-- --:--:--
4 OFF --/--/-- --:--:--
ON --/--/-- --:--:--
(UP)(DOWN)(CLEAR) (MENU)