(10/2000)
15
Automatic restart function
The video recorder can be programmed to rewind
automatically as soon as the tape runs out and re-
record on the same tape.
This automatic function can be overridden, after
corresponding programming, in the event of an
alarm arising (see page 25).
The REPEAT indication is displayed whenever the
automatic restart function is programmed as active.
Recording function activated from external signal
The video recorder can be programmed to allow
activation from an external signal source.
Note however that the recording function has to be
started manually in this case.
The REC indication appears on the display, along
with a tape running time of 00H.
Alarm recall list
This feature allows you to display a list of the last 16
alarm incidents, with the data shown in
chronological order. Once there are more than 16
incidents, the oldest item is automatically deleted.
- Stop the machine if it is still recording.
- Open the flap on the front of the unit and press
the MENU button. This will display the main
menu.
- Press the DOWN button repeatedly until ALARM
SET UP is marked, then press the ENTER button.
- Press the DOWN button repeatedly until ALARM
RECALL is marked, then press the ENTER
button. The alarm recall list will now be displayed.
- Press the DOWN button repeatedly once more if
you wish to display any further entries.
- Press the CLEAR button to delete the marked
entry.
- Finally, press the MENU button repeatedly until
the menu disappears from the display.
Operation
ALARM RECALL
1 05/11/00 18:02:42
2 04/29/00 04:32:19
3 04/29/00 03:59:56
4 --/--/-- --:--:--
5 --/--/-- --:--:--
6 --/--/-- --:--:--
7 --/--/-- --:--:--
8 --/--/-- --:--:--
(DOWN) (CLEAR) (MENU)