GAT NET.Lock 7020 System
Installation
30
HB_GAT-NETLOCK7020--EN_12
www.gantner.com
3.11
Installation in Lockers with Metallic Doors
The GAT NET.Lock 7020 can be installed on the left or right side of the inner locker wall depending on whether it is
a right or left-hinged locke
r door (see “3.7. Definition of the Door Hinge (Right or Left Door)). Two cutouts are required
in the door - one in the inner door sheet and one in the outer door sheet. The two parts of the GAT NET.Lock Bolt Set
7220 are mounted into these cutouts in the locker door. The door thickness must be between 18 and 26 mm (0.71 in
and 1.02 in). See Figure 3.10 and the following steps installation instructions.
1. GAT NET.Lock 7020
2. GAT NET.Lock Bolt Set 7220
3. 3 x mounting holes for the GAT NET.Lock 7020
4. 4 x mounting holes for the GAT NET.Lock BoltSet 7220
5. LED position
6. Label carrier
7. Front label
8. Cutout for GAT NET.Lock Bolt Set 7220
9. Cutout for label carrier
Figure 3.10 - Installation in a locker with metallic door (right-hinged)
Содержание GAT NET.Lock 7020 System
Страница 2: ......
Страница 36: ...GAT NET Lock 7020 System Installation 36 HB_GAT NETLOCK7020 EN_12 www gantner com ...
Страница 56: ...GAT NET Lock 7020 System Configuration and Operation 56 HB_GAT NETLOCK7020 EN_12 www gantner com ...
Страница 63: ......