background image

 

Part Number 3080006.001, Rev. D 

©2012, HES, Inc. 

                    1 

 

 

 

 

K100-620 Aperio 

Cabinet Lock Series 

Installation Instructions 

HES, Inc. 
Phoenix, AZ 
1.800.626.7590 

www.hesinnovations.com 

 

 

 

 

 

                                                                                                                                                            
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Machine 

screw with 

washer 

Card Reader Template 

Installation Hardware 

Strike Plate 

Antenna/Reader 

6-32 screws 

2X 

5/16” 

1” 

1-5/8” 

1-1/4” 

1-3/4” 

2-1/2” 

2X 

1X 

1X 

2X 

2X 

Shaft Extension 

Battery Cover 

Washer 

0-80x½” 

2-56x3/8” 

2-56x1-1/4” 

Battery 

Key Override Paddle 

1X 

1X 

1X 

1X 

2X 

1X 

1X 

1X 

Mounting 

Templates 

1X 

1X 

1X 

6 x 1/2” 

3X 

Aperio Cabinet Lock Components 

Quick Installation Summary 

Lock 

Body 

5. Connect 

2. Drill 

3. Configure 

1. Mark 

4. Install 

Aperio Hub 

1-7/8” 

 

2X 

Содержание K100-620 Aperio Series

Страница 1: ...mplate Installation Hardware Strike Plate Antenna Reader 6 32 screws 2X 5 16 1 1 5 8 1 1 4 1 3 4 2 1 2 2X 1X 1X 2X 2X Shaft Extension Battery Cover Washer 0 80x 2 56x3 8 2 56x1 1 4 Battery Key Override Paddle 1X 1X 1X 1X 2X 1X 1X 1X Mounting Templates 1X 1X 1X 6 x 1 2 3X Aperio Cabinet Lock Components Quick Installation Summary Lock Body 5 Connect 2 Drill 3 Configure 1 Mark 4 Install Aperio Hub 1 ...

Страница 2: ...orizontal centerline of the latch 2a Hold the lock body to the inside of the door and position it generally where you would like it to mount Locate lock centerline notch on the latch and use a pencil to mark this point on the inside of the cabinet door 2b Draw the horizontal latch centerline from this mark on the inside of the cabinet door 2c Next transfer this centerline to the inside of the cabi...

Страница 3: ...e 5a Peel off the protective layer of the Reader Template and align it to both holes drilled in the previous step 5b Drill only one 5 32 hole depending on the desired antenna reader orientations see below 5c Remove the Reader Template from the door NOTE Some antenna reader orientations may prevent use of the key override function For example in the door handing shown here manual override cannot be...

Страница 4: ...le If a Key Override is used install the Key Override Paddle on the arm of the lock body as shown here and firmly tighten the screw 8 Key Override Door Preparation If a Key Override is used drill a hole in the door based on cam length R 8a Measure cam length R 8b Calculate the distance from the lock features based on the image to the right 8c Drill a hole in the door based on the cam lock installa...

Страница 5: ...thickness of the cabinet door WARNING Make sure you avoid crimping the wires Crimped wires may prevent the Reader and Lock from functioning Table 2 10 Install the lock 10a Remove the battery cover from lock Place the lock on the inside of the door threading the cable through the lock 10b Using two 6 32 lock mount screws see table 2 for length attach the lock to the antenna reader Tighten the screw...

Страница 6: ...all the battery cover by inserting and tightening the provided screws 12f Present a valid iClass or 125kHz prox credential to unlock the cabinet lock Note Note See WEMN4 Aperio Programming Application for programming credential Note Always use new batteries installed with correct polarity Configure the lock before continuing Refer to the Aperio Technology Installation Manual for details 13 Place t...

Страница 7: ...ded 16 Install the double door strike plate 16a Place the strike plate over the holes on the 620 DD bracket Insert and tighten the two 6 32 X 5 16 screws provided with the 620 DD option 16b Close the door to verify installation Adjust the strike plate if necessary 16c After adjusting insert and tighten the lock down screw on the strike plate Place strike plate and adjust 14a b 14c Set strike plate...

Страница 8: ...ce actions Fig Lock Normal operation LED indication Access denied EAC offline Three red flashes 5 s each Access granted EAC offline or online One red flash 1 second One green flash 1 second Access denied EAC online Lock mechanism is blocked when closing 1 Continuous red flashes 125 seconds every 1 second Card read configurable One yellow flash 25 second Error in lock maintenance required 2 Ten red...

Страница 9: ...rity data corrupt 0x0008 6 Configuration data corrupt 0x0010 7 Battery power low 0x0020 8 RFID reader circuit error 0x0040 9 Voltage regulator error 0x0080 10 Card detection circuit error 0x0100 11 Secure area communication error 0x0200 12 Secure area memory corrupt 0x0400 13 Secure area sensor or motor error 0x0800 14 Radio modem communication error 0x1000 15 Radio modem memory corrupt 0x2000 16 ...

Страница 10: ...erference including interference that may cause undesired operation Conformité aux normes FCC Cet équipement a été testé et trouvé conforme aux limites pour un dispositif numérique de classe B conformément à la Partie 15 des règlements de la FCC Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans une installation résidentielle Cet équipement gén...