GAT NET.Lock 7020 System
Installation
www.gantner.com
HB_GAT-NETLOCK7020--EN_12
23
3.6
Door Status Function
In order to indicate whether the locker is occupied or not, the GAT NET.Lock 7020 has a feedback function that is
activated by the bolt set as soon as the locker door is closed.
Figure 3.4
– Door status function
3.7
Definition of the Door Hinge (Right or Left Door)
For installation, it is important to determine whether the door is hinged to the left or the right. This is defined as follows:
Figure 3.1 - Definition of the opening direction of lockers (left/right)
In this chapter, the installation for right-hinged doors is described. The installation process for left locker doors is in
principle the same as for right locker doors, only with reversed lock and door orientation.
NOTE!
If spring hinges are used in the locker door, ensure the spring strength is calibrated to allow correct operation
of the lock. Springs that are too strong can keep the bolt set permanently held in thereby activating the loc
k’s
electronics.