GAT ECO.Side Lock 7010 (NW) F/ISO
Operation
56
HB_GAT-ECOSide-Lock7010-FISO--EN_11
www.gantner.com
► Remove the DELETE MASTER data carrier from the reading field.
o
All MASTER data carriers are now deleted from the lock
o
The LED flashes green and red alternately and the new MASTER data carriers can be programmed.
► Within 5 seconds, hold the first MASTER data carrier next to the reading field.
o
When the data carrier is read correctly, the LED is green for 2 seconds.
► Remove the MASTER data carrier from the reading field.
o
The LED flashes green and red alternately. The second MASTER data carrier can now be
programmed.
► Repeat the process until all MASTER data carriers are programmed.
► When a MASTER data carrier is read for longer than 5 seconds during programming, the lock automatically
returns to the normal operating mode and the new MASTER data carriers are saved in the lock.
6.5.2
OPEN MASTER Data Carrier
The OPEN MASTER data carriers can unlock any GAT ECO.Side
Lock 7010 F/ISO in a system. If a user’s data
carrier is lost, an emergency opening of the corresponding locker can be carried out using an OPEN MASTER data
carrier. Compared to the MASTER data carrier, the OPEN MASTER data carrier can only unlock a locker, but cannot
lock the locker.
The OPEN MASTER data carrier is not included in the Basic Set and must be ordered separately if required. This
data carrier is only valid for the respective system.
NOTE!
The system operator must ensure that the OPEN MASTER
data carriers are stored in a safe location that is
secured against unauthorized access.
An OPEN MASTER data carrier can be used instead of an original MASTER data carrier. To program the OPEN
MASTER data carrier into a lock, read the data carrier at the lock. If already the max. amount of MASTER data carriers
(10) are programmed into the lock, the MASTER data carriers must first be deleted and the OPEN MASTER data
carrier must be programmed together with the required MASTER data carriers (max. total amount of 10).
6.5.3
DELETE MASTER Data Carrier
Formerly known as the RESET data carrier, the DELETE MASTER data carrier is used to delete all the MASTER
data carriers stored in the lock
. See section “6.5.1. MASTER Data Carriers”.
6.5.4
PROGRAM Data Carrier
For lockers operating in personal locker mode, the PROGRAM data carrier is used to authorize data carriers so they
can be used with the locker. The PROGRAM data carrier is also used to delete the existing authorizations of
personal lockers. See section “6.3.4. Personal Locker Programming Card Mode”.