Mounting and installation instructions

In order to mount the GAT Access 6600 onto a turnstile, a tubular 
mounting holder with 30 mm Ø is used (e.g., a GAT Holder 6010 L). The 
connecting cables are fed through the tubular holder and into the housing.

Opening the housing

The housing of the GAT Access 6600 must be opened to install the tubular 
holder. Unscrew and remove the 4 housing screws on the rear part while 
firmly holding the front part of the GAT Access 6600 to prevent it from 
falling. After the screws are removed, the front part can be lifted away.
 

Two clamps inside the housing are used to fasten the tubular holder. The 
lower clamp (1) is directly accessible and can be loosened accordingly to 
allow the tubular holder to be inserted.

In order to gain access to the second clamp (2), the electronics (3) must 
be removed. Loosen the two screws as indicated in the figure below (4) 
and swing the electronics 90 ° forward (5).

Attachment of the tubular holder and cable installation

Insert the GAT Access 6600 onto the tubular holder (7) until the stop (6) 
is reached.

Tighten the screws of the two clamps (1) + (2) firmly so that the GAT 
Access 6600 is secure and cannot be removed from the tubular holder.

Feed the connecting cables through the tubular holder. Connect the 
cables to the screw terminals (see next page). Use cable ties to secure 
the cabling to the holes provided in the retaining strip (8).

Remount the electronics in their original position and fasten the 2 screws 
(4). 

Take care not to damage the connecting cable.

Close the housing by placing the front part of the housing onto the 
rear part and secure them with the 4 screws. 

Take care to ensure the 

housing gasket is correctly inserted into the joint between the front 
and rear part and not damaged during this process.

Valid as from June 16

th

 2015 • Technical data subject to modifications without notice! 

DB_GAT-ACCESS6600--EN_11.indd • PartNo.: 822630

1

2

3

4

3

4

4

3

3

5

2x

2

6

7

6

1

7

8

7

6

8

7

8

Содержание GAT Access 6600 Series

Страница 1: ... facilities such as public swimming pools indoor and outdoor water facilities and attraction parks The terminal is mounted directly onto turnstiles or similar access control hardware and provides convenient operation for the facility guests Identification at the terminal is achieved either with barcode tickets 1D and 2D or with contact free RFID data carriers Radio Frequency Identification The cle...

Страница 2: ...s 4 x relays configurable NO NC Switching voltage DC max 30 V SELV Switching voltage AC max 15 V SELV Continuous current max 1 8 A Switching power max 54 W 27 VA Connection terminals 0 5 to 1 5 mm2 Housing material Plastic with safety glass front Dimensions housing approx 280 6 x 194 x 135 5 mm approx 8 21 x 7 64 x 5 33 inch Permitted ambient temperature 25 to 50 C 13 to 122 F Storage temperature ...

Страница 3: ...he figure below 4 and swing the electronics 90 forward 5 Attachment of the tubular holder and cable installation Insert the GAT Access 6600 onto the tubular holder 7 until the stop 6 is reached Tighten the screws of the two clamps 1 2 firmly so that the GAT Access 6600 is secure and cannot be removed from the tubular holder Feed the connecting cables through the tubular holder Connect the cables t...

Страница 4: ... such as turnstiles etc each relay provides NC normally closed and NO normally open operation The permitted switching power levels see technical data must never be exceeded Optocoupler inputs Potential free inputs for status detection An input voltage must be applied to activate the input This voltage can be supplied by the terminal s power source or from an external power source Please observe th...

Отзывы: