Menu Guidance
15
Hydromette BL A plus
measurement
Type 6
Resistance
measurement
Type 7
Resistance
measurement
Type 91
Capacitive
measurement
Wood type adjuster in 0.1
steps
Type 92
Capacitive
measurement
for rough sawn timber
Type 93
Capacitive
measurement
for
thin
material
thicknesses
Table 3-2: Measuring Methods / Type Selection
3.1.2
Resistance-based Measurement
The resistance measurement involves a seven-stage wood type
correction, the selection of which is made via a wood type table
with over 300 different wood types. The optimum electrodes for the
respective measuring task can be connected to the BNC socket
using a coaxial cable. A coaxial cable with special insulation should
be used to avoid measurement errors. A compensation
temperature can be set manually in steps of 1 °C for temperature
compensation of the measured values.
Main menu
Settings
Type
3.1.3
Capacitive Measurement
The ten-step wood type setting of the capacitive measurement is
carried out in 0.1 steps as default.