background image

3. Maintenance

Routine Maintenance

The cleaning of lens must be carried out periodically to optimize light output. Cleaning 
frequency depends on the environment in which the fixture operates: damp, smokey, or 
particularly dirty surrounding can cause greater accumulation of dirt on the fixture’s 
optics.

    • Clean with a damp, soft cloth..

    • Always dry the parts carefully.

    • Clean the external optics at least every 20 days in demanding environments.

Troubleshooting Problems

The following are a few common problems that may occur during operation.  Here are 
some suggestions for easy troubleshooting:

A. The unit does not work:

Check that the unit is plugged in to a working power connector.

Press the menu button to confirm that the unit is powered on.  If the screen does 
not light up, the unit has no power.

B. Not Responding to the DMX Controller

Check DMX cables to verify that they are plugged in and functional.

Check the DMX address and mode – does it match the address and mode patched 
in the lighting console or software?

Plug the light directly into the DMX controller with a cable that you know is good.  
Unplug all other lights – does it work?

Try to use another DMX controller.

 Rosé LED 200 Zoom – GAMMA LED Vision

Page 10 of 11

Содержание Rose LED Zoom

Страница 1: ...Rosé LED Zoom 200w Cold White Warm White Fresnel with Motorized Zoom Rosé LED 200 Zoom GAMMA LED Vision Page 1 of 11 User Manual ...

Страница 2: ... 2 Setup and Operation 7 Using the LCD Menu and Buttons 7 Menu Operation 8 DMX Setup 8 DMX Basics 8 DMX Wiring 8 DMX Modes and Configuration 10 Standalone Mode and Configuration 10 3 Maintenance 11 Routine Maintenance 11 Troubleshooting Problems 11 4 Technical Specifications 12 Photometric Reports 12 Rosé LED 200 Zoom GAMMA LED Vision Page 2 of 11 ...

Страница 3: ...osé LED 200 Zoom to hang the fixture from the mount s on the fixture s yoke As an added safety measure be sure to attached at least one properly rated safety cable to the fixture using on of the safety cable rigging point integrated in the base assembly or on the yoke Features Voltages AC 100V 240V 50 60Hz Power Consumption 250W 230V LED Light Source 200W Cool White Warm White COB Led Manufacturer...

Страница 4: ...w the device when mounting removing or servicing the fixture From a ceiling or set on a flat level surface see illustration below Be sure this fixture is kept at least 0 5m 1 5ft away from any flammable materials decoration etc Always use and install the supplied safety cable as a safety measure to prevent accidental damage and or injury in the event the clamp fails DO NOT connect the device to an...

Страница 5: ...by misuse or improper handling of the products and in accordance with instructions and specifications of manual Warranty terms are as follows LED Fixtures Indoor 2 Years Outdoor IP 54 or higher 1 Year Lamp Fixtures 1 year excludes the lamp LED Video Products Indoor 2 Years Outdoor IP 54 or higher 1 Year Controllers 2 years Batteries 6 months All Trussing Related Products and Accessories 1 Year Ple...

Страница 6: ... minute and then exit the menu mode automatically When there is no power connection press the UP button for 1 minute to enter the menu mode After setting press MENU button to return to the previous menu Menu Operation MENU A001 Set DMX Address 1 512 CC99 Automated programs color chasing Up Down keys change speed from 01 99 DE99 Automated programs color pulsing Up Down keys change speed from 01 99 ...

Страница 7: ... connect in what is called a daisy chain Your first DMX cable will plug it s male DMX connector into the female DMX connector on your lighting console The remaining female connector will then connect to the DMX input on your first light You may then connect your next fixture to the output of your first light and continue the chain 32 Fixture Rule DMX only allows you to connect up to 32 fixtures in...

Страница 8: ...is helps in preventing corruption of the digital control signal by electrical noise and reflections The DMX terminator is simply an XLR plug with a 120 Ω resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below Rosé LED 200 Zoom GAMMA LED Vision Page 8 of 11 ...

Страница 9: ... Master Intensity Control 2 Warm White 0 255 Warm White Control 3 Cool White 0 255 Cool White Control 4 Strobe 0 255 Strobe Control 5 Zoom 0 255 Zoom Control 5 60 6 Macros 0 100 Quick Jump 101 150 Gradual Change 151 200 Pulse Change 201 255 Sound Active Mode 7 Macro Speed 0 255 Built In Program Speed Slow to Fast Rosé LED 200 Zoom GAMMA LED Vision Page 9 of 11 ...

Страница 10: ...at may occur during operation Here are some suggestions for easy troubleshooting A The unit does not work Check that the unit is plugged in to a working power connector Press the menu button to confirm that the unit is powered on If the screen does not light up the unit has no power B Not Responding to the DMX Controller Check DMX cables to verify that they are plugged in and functional Check the ...

Страница 11: ... Strobe 0 25F P S Zoom Angle 5 60 Control DMX512 3 pins interfaces RDM Control Protocol 3 Channels in standard mode Master Salve Synchronous Control Mode DMX512 Master Slave Auto Sound Housing Cast aluminum IP20 Indoor Working Environment 10 C 40 C Box Dimension Inner 300 300 510MM Net weight 7 50Kg Photometric Reports Photometric Data FC at Center Zoom IN 5 FC at Center Zoom Out 60 1m 1120 2m 257...

Отзывы: