Service Manual
22/46
Issue 3.1
Ref. NR-00019-ENG
http://www.gamapur.com/
w) Allow the materials to come out of the recirculating hoses until the tanks are empty.
x) Turn the general switch
“OFF”.
y) Close the manual valves at the bottom of the tanks.
z) Close the recirculation manual valves.
aa) Fill the product tanks with new product.
bb) Open the manual valves at the bottom of the tanks.
cc) Open the recirculation manual valves.
dd) Turn the general switch
“ON”.
ee) Push the
“START” green button. The temperature regulator displays not will light on.
Check the product pumps begin to move slowly.
If necessary, increase the pneumatic pressure by turning the regulator clockwise until
the product pumps begin to move slowly.
ff) Allow the DOTP agent to come out of the recirculation hose until see the new product.
gg) Allow the products to come out until you see that only DOTP cleaning agent comes out
free of impurities.
hh) Close the
“RETRATC” valve (horizontal position).
ii) Turn the general switch
“OFF” and return to the position “On“ the switch of the heaters.
jj) Clean and move the recirculation hoses to the tanks again.
kk) Close the manual valves at the bottom of the tanks.
ll) The cleaning process is complete and you can proceed as normal for new products.