Manual de Servicio
12/46
Issue 3.1
Ref. NR-00019-ENG
http://www.gamapur.com/
4. Hoses (OPTIONAL)
Hose heating is activated and deactivated by
the orange pushbutton located at the front of
the transformer. It will lit up when heating is
activated.
Turn the potentiometer clockwise to increase
amps, and anti-clockwise if you wish to
decrease amps. Adjustment ranges from 0 to
50 amps.
Take the values below as an approximate
reference to select the intensity that allows
reaching
the
requested
application
temperature.
30 A
38º C 100º F
35 A
48º C 118º F
40 A
60º C 140º F
45 A
75º C 167º F
50 A
80º C 176º F
Turn the potentiometer clockwise until the screen shows the required amps for a quick pre-
heating.
NOTE:
The circuit breaker software of the transformer has a safety system to prevent
the hoses from being exposed to high temperatures during long periods of time.
If you have selected a potential over 35 amperes, after 20 minutes, the potential will
automatically regulate to 35 amperes.
This potential cannot be set above 35 amperes until the heater is disconnected from the
hoses and reconnected.
5. Heaters Switch
Turns the electric supply to the control heaters unit ON and OFF.