Manual de Servicio
36/46
Issue 3.1
Ref. NR-00019-ENG
http://www.gamapur.com/
Hose Heating (Optional)
WARNING!
Before resolving any kind of defect, make sure all of the pushbuttons are
off, that the general switch is in shutdown position and that the unit is disconnected from
the power supply source. Never handle the inside of the control panel with the unit
connected to the power supply. The hoses can reach high temperatures; wait until they
have cooled before handling.
Follow the recommended procedure in the order indicated, to try to solve the problem and avoid
costly repairs. Make sure all the automatic switches and control elements are in the correct
working position before determining the existence of a fault.
PROBLEMS
SOLUTIONS
The hose is hot, but fails to reach the selected temperature.
1-2
The hose is not hot.
2-3-4-5
Only the sections of the hose closest to the unit are heated.
5
The automatic switch trips.
3
SOLUTIONS
1. Hose Length
The
Easy Spray
has been designed to work with a maximum hose length of 48 meters /160 ft.
A longer length will render the heating capacity less effective. Under extreme environmental
conditions, the hose heating system may be affected and fail to reach the required temperature.
2. Hose Transformer
The transformer offers the option of connecting to a 40 V output voltage valid for the connection
of hose sections with a total length of up to 48 meters. If the connection is performed incorrectly,
the hoses will not reach the required temperature. On the transformer display appears (00).
The hose connection system includes special terminals (fast lock) to facilitate the electrical
connection to the transformer and between the different sections installed in the unit.
3. Automatic Switch
This protects the secondary circuit of the transformer. The switch is located on the front of the
transformer; make sure it is turned on, otherwise turn it on. Replace it with one of an equal
amperage if the switch fails to work correctly. If the automatic switch is not working; on the
transformer display appears (00).
CAUTION!
The replacement of the automatic switch with another of different
characteristics may cause damage to the equipment and put the operator at risk.
4. Triac
This determines that the triac is faulty when all of the previous checks have been correct.
Replace the triac if it fails to work correctly.