© Galvin Engineering Pty Ltd
Product Installation Guidelines
Version 1.1, 13 May 2021, Page
3
of 4
ADJUSTING TIME FLOW
1. Disassemble
−
Dismount the button head
−
Remove the grub screw with a 1.5 mm
allen-key (not supplied)
2. Adjust stop-ring
−
Turn the stop-ring clockwise to increase flow
time or anti-clockwise to reduce it.
3. Fix position
−
Orientate the stop ring to allow the refitting
of the grub screw
4. Reassemble
−
Reassemble completely paying attention to
align the hole in the spindle with the grub screw