background image


 

 
Remove the screw from the test point and insert the hose or test probe of the 
manometer or draught gauge.   Record the reading in pascals (Pa).  The optimum reading 
should be in the range of 12-15Pa.  A flue draught may exceed 15Pa but must not exceed 
24Pa.  Anything above 24Pa may result in the over-firing of the stove. As a direct 
consequence of this the fuel consumption will be excessive which may result in a 
chimney fire.  Remove the hose or test probe and replace the screw confirming the test 
point is sealed. 
 

 

 
If the flue draught is outside the specified range for the appliance, remedial action is 
necessary to correct the problem and allow the chimney to operate at the correct 
draught.  This might typically include adding a draught stabilizer to reduce too high a 
draught or lining and insulating an overly large chimney if the draught is too low.  
The chimney must be swept before fitting a liner to the stove and it is a condition of the 
warranty  that  it  must  be  swept  every  twelve  months  thereafter,  but  not  limited  to 
depending on use.  If used regularly, it is recommended that your chimney is swept every 
six months. 

 

 

Содержание FIREFOX 5 ECO

Страница 1: ...the controls and the correct fuel types to burn focusing on both efficiency and environmental considerations Stoves operate at very high temperatures All persons including children must be warned of t...

Страница 2: ...stallation Information Page 11 2 4 Operation Page 13 3 0 MAINTENANCE 3 1 General Maintenance Page 18 3 2 Seasonal Maintenance Page 20 4 0 SAFETY NOTES AND TROUBLESHOOTING 4 1 CO Alarms Page 20 4 2 Ove...

Страница 3: ...4 Flue gas mass flow g s 3 8 Mean CO emission 13 O2 Nmg m3 0 05 Mean CnHm emission 13 O2 Nmg m3 44 Mean NOx emission 13 O2 Nmg m3 73 Mean Particulates 13 O2 Nmg m3 26 Essential characteristics burning...

Страница 4: ...4 1 2 STOVE DIMENSIONS...

Страница 5: ...ave a detrimental effect on the environment ITEM DESCRIPTION ITEM DESCRIPTION 1 Secondary control knob 12 Ash pan 2 Stove lid 13 Primary control knob 3 Flue collar 14 Door handle 4 Flue blanking plate...

Страница 6: ...taken to avoid the possibility of personal injury The installation and servicing must be in accordance with the Health and Safety at Work Act and the manufacturer of the stove accepts no liability if...

Страница 7: ...oid damage and refit after installation On completion of the installation and commissioning ensure that the operating instructions for the stove are left with the end user The installer must advise th...

Страница 8: ...suitable period of time for any fire cement and mortar to dry out before lighting the stove Once the stove is under fire check all seals for soundness and check that the flue system is functioning cor...

Страница 9: ...ace the screw confirming the test point is sealed If the flue draught is outside the specified range for the appliance remedial action is necessary to correct the problem and allow the chimney to oper...

Страница 10: ...ler for a detailed survey Typical Installation for Inglenook Fireplaces Top Flue Inglenook fireplaces can have very large bore chimneys Check with your installer you are likely to require a stainless...

Страница 11: ...absolute guidance on exact distances Materials above the stove are far more likely to overheat than those beside or underneath As a guide the limiting temperature for SOLID timber is 60 C above ambie...

Страница 12: ...ing into account the loading of the installation whole 2 3 3 Ventilation If the room in which the stove is fitted has an air permeability of more than 5 0m3 h m2 typical of house built pre 2008 then o...

Страница 13: ...uld be closed when a wood fire is established for the best efficiency but can be used to give a wood fire a boost when it is dying out 2 4 2 Secondary Air controllable Secondary air is controlled via...

Страница 14: ...ire with starting fuel i e dry kindling timber and or firelighters with either fuel chosen wood or smokeless coal It is normal to see smoke coming from the open stove door at this stage Light the fire...

Страница 15: ...ur installer when the commissioning takes place 2 4 6 Other Solid Fuel Burning Always clean out the ash pan before refuelling and do not let the ash build up to the underside of the grate bars this wi...

Страница 16: ...3 75mm it would take about 3 years to dry A dry log will produce up to four and a half times more heat output than a freshly cut log Wet logs take heat to dry and if burned in this state will cause i...

Страница 17: ...r obtained for use in smoke control areas have been authorised and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted for each area of administration...

Страница 18: ...taller 3 1 1 Baffle Plate Removal and Replacement Note the position before removal To remove baffle plate firmly push the baffle plate upwards with one hand then use another hand to manoeuvre the side...

Страница 19: ...whilst the stove is hot wait until it has cooled down The finish can be renovated with high temperature stove paint as supplied by the manufacturer Aerosols must never be used when the stove is hot or...

Страница 20: ...new or replacement appliance also Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instructions See page 8 of this m...

Страница 21: ...uelling or de ashing must not be tolerated and if apparent the stove must not be used until the chimney system and installation whole has been checked accordingly If the spillage of the combustion pro...

Страница 22: ...be blocked closed or restricted in any way 4 7 FUEL QUALITY Only burn dry seasoned timber soft woods have a lower heat output than hard woods Solid fuels vary in heat value and sulphur content therefo...

Страница 23: ...raphite high temperature paint Stove Glass Cleaner Spare Rope Rope Seal Adhesive CO Detector Gallery Stove Fan Gallery Stove Thermometer Wood Moisture Meter Spare Glove Permanent Ventilators Purpose b...

Страница 24: ...24 Brought to you by Percy Doughty Co Imperial Point Express Trading Estate Stone Hill Road Farnworth Bolton BL4 9TN 01204 868 550 www percydoughty com...