background image


 

 
This  stove  must  not  share  a  chimney  with  any  other  appliance  -  this  includes  gas 
appliances as well as solid fuel.  
Where a masonry chimney is believed to have previously served an open fire installation, 
it is possible that the higher flue gas temperature from a  closed appliance may loosen 
deposits  that  were  previously  firmly  adhered,  with  the  consequential  risk  of  a  flue 
blockage. It is therefore recommended that a masonry chimney should be swept a second 
time within a month of regular use after installation. It is important to clean the stove flue-
ways,  flue-pipe  and  chimney  prior  to  operating  after  a  prolonged  shut-down  period, 
keeping  the  stove  well  ventilated  during  long  periods of  not  using  is  also  important  to 
prevent a build-up of condensation and rust forming. 

Check  the  chimney  is  in  good  condition,  dry,  free  of  cracks,  obstructions  and  integral 
throughout.  The cross sectional diameter of the brick chimney should not be less than 
125mm and not more than 230mm. If any of these requirements are not met, the chimney 
should be lined by a suitable method using a liner with a cross sectional diameter not less 
than 125mm. 

On completion of the installation allow a suitable period of time for any fire cement and 
mortar to dry out, before lighting the stove. Once the stove is under fire check all seals for 
soundness and check that the flue system is functioning correctly and that all products of 
combustion  are  being  removed  safely  and  vented  to  atmosphere  via  the  chimney 
termination point, which must only be an approved terminal.  

When installing this stove, a 125mm flue liner may be used in accordance with BS8303 
and current Building Regulations. The chimney and connecting flue pipe should not be less 
than the size of the outlet socket (collar) of the stove at any point. 

The chimney height and the position of the chimney terminal must be in accordance with 
the current Building Regulations and conform to the latest edition of BS EN 15287-1:2007, 
Design, Installation and Commissioning of Chimneys.  

On commissioning the Stove, a flue draught reading must be taken and documented on 
the commissioning certificate this reading ensures the stove is operating within its 
designed parameters and its optimum efficiency. A sample point has been included on 
this appliance and is located on the top right-hand side of the stove. 

Light the appliance following the procedure on Page 14.  Allow the appliance and 
chimney to reach their normal operating conditions.  

Care should be taken when 

proceeding with the test as all stove parts will now

 

be hot

.  

Содержание FIREFOX 5 ECO

Страница 1: ...the controls and the correct fuel types to burn focusing on both efficiency and environmental considerations Stoves operate at very high temperatures All persons including children must be warned of t...

Страница 2: ...stallation Information Page 11 2 4 Operation Page 13 3 0 MAINTENANCE 3 1 General Maintenance Page 18 3 2 Seasonal Maintenance Page 20 4 0 SAFETY NOTES AND TROUBLESHOOTING 4 1 CO Alarms Page 20 4 2 Ove...

Страница 3: ...4 Flue gas mass flow g s 3 8 Mean CO emission 13 O2 Nmg m3 0 05 Mean CnHm emission 13 O2 Nmg m3 44 Mean NOx emission 13 O2 Nmg m3 73 Mean Particulates 13 O2 Nmg m3 26 Essential characteristics burning...

Страница 4: ...4 1 2 STOVE DIMENSIONS...

Страница 5: ...ave a detrimental effect on the environment ITEM DESCRIPTION ITEM DESCRIPTION 1 Secondary control knob 12 Ash pan 2 Stove lid 13 Primary control knob 3 Flue collar 14 Door handle 4 Flue blanking plate...

Страница 6: ...taken to avoid the possibility of personal injury The installation and servicing must be in accordance with the Health and Safety at Work Act and the manufacturer of the stove accepts no liability if...

Страница 7: ...oid damage and refit after installation On completion of the installation and commissioning ensure that the operating instructions for the stove are left with the end user The installer must advise th...

Страница 8: ...suitable period of time for any fire cement and mortar to dry out before lighting the stove Once the stove is under fire check all seals for soundness and check that the flue system is functioning cor...

Страница 9: ...ace the screw confirming the test point is sealed If the flue draught is outside the specified range for the appliance remedial action is necessary to correct the problem and allow the chimney to oper...

Страница 10: ...ler for a detailed survey Typical Installation for Inglenook Fireplaces Top Flue Inglenook fireplaces can have very large bore chimneys Check with your installer you are likely to require a stainless...

Страница 11: ...absolute guidance on exact distances Materials above the stove are far more likely to overheat than those beside or underneath As a guide the limiting temperature for SOLID timber is 60 C above ambie...

Страница 12: ...ing into account the loading of the installation whole 2 3 3 Ventilation If the room in which the stove is fitted has an air permeability of more than 5 0m3 h m2 typical of house built pre 2008 then o...

Страница 13: ...uld be closed when a wood fire is established for the best efficiency but can be used to give a wood fire a boost when it is dying out 2 4 2 Secondary Air controllable Secondary air is controlled via...

Страница 14: ...ire with starting fuel i e dry kindling timber and or firelighters with either fuel chosen wood or smokeless coal It is normal to see smoke coming from the open stove door at this stage Light the fire...

Страница 15: ...ur installer when the commissioning takes place 2 4 6 Other Solid Fuel Burning Always clean out the ash pan before refuelling and do not let the ash build up to the underside of the grate bars this wi...

Страница 16: ...3 75mm it would take about 3 years to dry A dry log will produce up to four and a half times more heat output than a freshly cut log Wet logs take heat to dry and if burned in this state will cause i...

Страница 17: ...r obtained for use in smoke control areas have been authorised and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted for each area of administration...

Страница 18: ...taller 3 1 1 Baffle Plate Removal and Replacement Note the position before removal To remove baffle plate firmly push the baffle plate upwards with one hand then use another hand to manoeuvre the side...

Страница 19: ...whilst the stove is hot wait until it has cooled down The finish can be renovated with high temperature stove paint as supplied by the manufacturer Aerosols must never be used when the stove is hot or...

Страница 20: ...new or replacement appliance also Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instructions See page 8 of this m...

Страница 21: ...uelling or de ashing must not be tolerated and if apparent the stove must not be used until the chimney system and installation whole has been checked accordingly If the spillage of the combustion pro...

Страница 22: ...be blocked closed or restricted in any way 4 7 FUEL QUALITY Only burn dry seasoned timber soft woods have a lower heat output than hard woods Solid fuels vary in heat value and sulphur content therefo...

Страница 23: ...raphite high temperature paint Stove Glass Cleaner Spare Rope Rope Seal Adhesive CO Detector Gallery Stove Fan Gallery Stove Thermometer Wood Moisture Meter Spare Glove Permanent Ventilators Purpose b...

Страница 24: ...24 Brought to you by Percy Doughty Co Imperial Point Express Trading Estate Stone Hill Road Farnworth Bolton BL4 9TN 01204 868 550 www percydoughty com...

Отзывы: