Copyright © Gallagher Group Limited

 

Cable distance

Cable type

Cable format*

HBUS  

single reader 

connected 
using data 

only in a single 

cable

Cardax IV 

single reader 

connected 
using data 

only in a single 

cable***

HBUS/Cardax IV 

single reader 

connected  using  

power and 

data in a single 

cable****

CAT 5e or 

better**

4 twisted pair each 2 x 

0.2 mm

(24 AWG)

500 m (1640 ft) 200 m (650 ft)

100 m (330 ft)

BELDEN 

9842**

 

(shielded)

2 twisted pair each 2 x 

0.2 mm

(24 AWG)

500 m (1640 ft) 200 m (650 ft)

100 m (330 ft)

SEC472

4 x 0.2 mm

2  

Not 

twisted pairs (24 AWG)

400 m (1310 ft) 200 m (650 ft)

100 m (330 ft)

SEC4142

4 x 0.4 mm

2  

Not 

twisted pairs (21 AWG)

400 m (1310 ft) 200 m (650 ft)

150 m (500 ft)

C303900/

C303901 

Gallagher 

HBUS Cable

2 Twisted pair each 2 

x 0.4 mm

(21 AWG, 

Data) and 2 x 0.75 

mm

Not Twisted Pair 

(~18 AWG, Power)

500 m (1640 ft) 200 m (650 ft)

450 m (1490 ft)

* The matching of wire sizes to equivalent wire gauges are only approximate.

** Recommended cable types for optimal HBUS RS485 performance.

 

*** Not applicable for PIV or Bluetooth® enabled reader installations.

 

**** Tested with 13.6V at start of cable.

Notes:

• 

Shielded cable may reduce the obtainable cable length.  Shielded cable should be 

grounded at the Controller end only.  

• 

If other cable types are used, operating distances and performance may be reduced 

depending on the cable quality.

• 

HBUS allows up to 20 readers to be connected to a single cable.  Each reader requires 

13.6 Vdc to function correctly.  The cable length and the number of readers connected will 

have an impact on the voltage at each reader.

Distance between readers

The distance separating any two proximity readers must not be less than 200 mm (8 in) in all directions. 

When mounting a proximity reader on an internal wall, check that any reader fixed to the other side of 

the wall is not less than 200 mm (8 inches) away.

200 mm

  

   200 mm

Содержание C300470

Страница 1: ...T15 Reader Installation Note T15 MIFARE Reader Black C300470 T15 MIFARE Reader White C300471 T15 Multi Tech Reader Black C300480 T15 Multi Tech Reader White C300481 T15 PIV Reader Black C305470 T15 P...

Страница 2: ...eness and it should not be relied on as such To the extent permitted by law all express or implied or other representations or warranties in relation to the information are expressly excluded Neither...

Страница 3: ...Copyright Gallagher Group Limited Contents 1 Introduction 4 2 Before you begin 4 3 Distance between readers 7 4 Installation 7 5 LED indications 10 6 Accessories 10 7 Technical specifications 11 8 App...

Страница 4: ...ader C300470 C300471 ISO 14443A MIFARE DESFire EV1 EV2 MIFARE Plus and MIFARE Classic cards vEL7 80 HBUS only None vEL7 00 vEL1 02 T15 Multi Tech Reader C300480 C300481 ISO 14443A MIFARE DESFire EV1 E...

Страница 5: ...anded security cable This cable allows the transmission of data 2 wires and power 2 wires When using a single cable to carry both power supply and data both the power supply voltage drop and data requ...

Страница 6: ...devices HBUS Device Terminate HBUS Device HBUS Device HBUS Device HBUS Device HBUS Device HBUS Device Terminate Remove the on board termination jumper RS485 1 T or Star circuits are not permitted bet...

Страница 7: ...WG Power 500 m 1640 ft 200 m 650 ft 450 m 1490 ft The matching of wire sizes to equivalent wire gauges are only approximate Recommended cable types for optimal HBUS RS485 performance Not applicable fo...

Страница 8: ...ole this is the centre hole for which the building cable will exit the mounting surface and the two fixing holes 2 Run the building cabling out through the centre hole and through the reader bezel 3 S...

Страница 9: ...BUS A Green HBUS B Brown CDXIV TX White CDXIV RX Blue HBUS Reader Note To terminate an HBUS Reader connect the Orange HBUS Termination wire to the Green HBUS A wire Cardax IV Reader connection Positiv...

Страница 10: ...h the Controller but reader is not configured 1 Flash Amber Configured to a Controller but reader is not assigned to a door or elevator car On Green or Red Fully configured and functioning normally Gr...

Страница 11: ...eight 139 mm 5 47 inches Width 44 mm 1 73 inches Depth 23 mm 0 9 inches Maximum number of readers on one HBUS cable 20 1 The reader is idle 2 Maximum reader current during credential read 3 The curren...

Страница 12: ...ial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communic...

Страница 13: ...11 February 2022 Copyright Gallagher Group Limited 9 Mounting dimensions IMPORTANT This picture is not to scale therefore use the measurements provided 44 mm 1 73 139 mm 5 47 13 mm 1 2 diameter hole...

Отзывы: