Gallagher C300470 Скачать руководство пользователя страница 12

Page  12   

3E4237 Gallagher T15 Reader | Edition 11 | February 2022

 

Copyright © Gallagher Group Limited

Approvals and Compliance Standards

This symbol on the product or its packaging indicates that this product must not be disposed 

of with other waste. Instead, it is your responsibility to dispose of your waste equipment by 

handing it over to a designated collection point for the recycling of waste electrical and electronic 

equipment. The separate collection and recycling of your waste equipment at the time of disposal 

will help conserve natural resources and ensure that it is recycled in a manner that protects human 

health and the environment. For more information about where you can drop off your waste 

equipment for recycling, please contact your local city recycling office or the dealer from whom 

you purchased the product.
This product complies with the environmental regulations for the Restriction of Hazardous 

Substances in electrical and electronic equipment (RoHS). The RoHS directive prohibits the use of 

electronic equipment containing certain hazardous substances in the European Union.

FCC

 

Industry 
Canada 

Industrie 
Canada

This device complies with part 15 of the FCC Rules. Operation is subject to the following two 

conditions: (1) This device may not cause harmful interference, and (2) this device must accept any 

interference received, including interference that may cause undesired operation.

Note:

  Changes or modifications not expressly approved by Gallagher Limited could void the user's 

authority to operate this equipment.

Note:  

This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 

protection against harmful interference in a residential installation.  This equipment generates, 

uses and can radiate radio frequency energy and, if not installed and used in accordance with 

the instructions, may cause harmful interference to radio communications.  However, there is no 

guarantee that interference will not occur in a particular installation.  If this equipment does cause 

harmful interference to radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the interference by one or more of 

the following measures:

• 

Reorient or relocate the receiving antenna. 

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

This 

device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to 

the following two conditions: (1) this device may not cause interference, and (2) this device must 

accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio 

exempts de licence.  L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil 

ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage 

radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

UL 

Installations

Please refer to the document 

"3E2793 Gallagher Command Centre UL Configuration 

Requirements"

 for a guide to configuring the Gallagher system to the appropriate UL Standard.  

Installers must ensure t

hese instructions are followed to ensure the installed system is UL 

compliant.

AS/NZS IEC 60839.11.1:2019 Grade 4, Class II

C300480 only 

The C300480 variant of the T15 Readers is the only variant that complies with BIS.

US - Equipment: com, burg and acc reader

 

CA - Equipment: com, burg reader

Содержание C300470

Страница 1: ...T15 Reader Installation Note T15 MIFARE Reader Black C300470 T15 MIFARE Reader White C300471 T15 Multi Tech Reader Black C300480 T15 Multi Tech Reader White C300481 T15 PIV Reader Black C305470 T15 P...

Страница 2: ...eness and it should not be relied on as such To the extent permitted by law all express or implied or other representations or warranties in relation to the information are expressly excluded Neither...

Страница 3: ...Copyright Gallagher Group Limited Contents 1 Introduction 4 2 Before you begin 4 3 Distance between readers 7 4 Installation 7 5 LED indications 10 6 Accessories 10 7 Technical specifications 11 8 App...

Страница 4: ...ader C300470 C300471 ISO 14443A MIFARE DESFire EV1 EV2 MIFARE Plus and MIFARE Classic cards vEL7 80 HBUS only None vEL7 00 vEL1 02 T15 Multi Tech Reader C300480 C300481 ISO 14443A MIFARE DESFire EV1 E...

Страница 5: ...anded security cable This cable allows the transmission of data 2 wires and power 2 wires When using a single cable to carry both power supply and data both the power supply voltage drop and data requ...

Страница 6: ...devices HBUS Device Terminate HBUS Device HBUS Device HBUS Device HBUS Device HBUS Device HBUS Device Terminate Remove the on board termination jumper RS485 1 T or Star circuits are not permitted bet...

Страница 7: ...WG Power 500 m 1640 ft 200 m 650 ft 450 m 1490 ft The matching of wire sizes to equivalent wire gauges are only approximate Recommended cable types for optimal HBUS RS485 performance Not applicable fo...

Страница 8: ...ole this is the centre hole for which the building cable will exit the mounting surface and the two fixing holes 2 Run the building cabling out through the centre hole and through the reader bezel 3 S...

Страница 9: ...BUS A Green HBUS B Brown CDXIV TX White CDXIV RX Blue HBUS Reader Note To terminate an HBUS Reader connect the Orange HBUS Termination wire to the Green HBUS A wire Cardax IV Reader connection Positiv...

Страница 10: ...h the Controller but reader is not configured 1 Flash Amber Configured to a Controller but reader is not assigned to a door or elevator car On Green or Red Fully configured and functioning normally Gr...

Страница 11: ...eight 139 mm 5 47 inches Width 44 mm 1 73 inches Depth 23 mm 0 9 inches Maximum number of readers on one HBUS cable 20 1 The reader is idle 2 Maximum reader current during credential read 3 The curren...

Страница 12: ...ial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communic...

Страница 13: ...11 February 2022 Copyright Gallagher Group Limited 9 Mounting dimensions IMPORTANT This picture is not to scale therefore use the measurements provided 44 mm 1 73 139 mm 5 47 13 mm 1 2 diameter hole...

Отзывы: