Page 11
3E4237 Gallagher T15 Reader | Edition 11 | February 2022
Copyright © Gallagher Group Limited
7 Technical specifications
Routine maintenance:
Not applicable for this reader
Cleaning:
This reader should only be cleaned with a clean, lint free, damp cloth
Voltage:
13.6 Vdc
Current
3
:
MIFARE Reader
Multi Tech Reader
Idle
1
Maximum
2
Idle
1
Maximum
2
50 mA
77 mA
81 mA
136 mA
Temperature range:
-35 °C to +70 °C
4
Note: Direct sunlight may increase the internal reader temperature
above the ambient temperature level
Humidity:
0 - 95% non-condensing
5
Environmental protection:
IP68
6
Impact rating:
IK07
6
Unit dimensions:
Height 139 mm (5.47 inches)
Width 44 mm (1.73 inches)
Depth 23 mm (0.9 inches)
Maximum number of readers
on one HBUS cable:
20
1
The reader is idle.
2
Maximum reader current during credential read.
3
The current values stated above have been reported using the default configuration for a reader
in Command Centre. Changing the configuration may vary the current value. Reader currents
verified by UL are provided in the document
"3E2793 Gallagher Command Centre UL Configuration
Requirements"
.
4
Gallagher T Series readers are UL temperature tested and certified for operation in 0
o
C - 49
o
C (indoor)
and -35
o
C - +66
o
C (outdoor).
5
Gallagher T Series readers are UL humidity tested and certified to 85% and have been independently
verified to 95%.
6
Environmental protection and impact ratings are independently verified.