25
01.02.2021
Cod. 80005850a - GB
Pos.
Keys
2
/
3
SET
4
5
6
1
AUX
Function
To switch on and off the lighting (if any)
To start manual defrost
To display or modify the set point
UP arrow
—
to increase the set point value
DOWN arrow
—
to decrease the set point value
Stand
-
by of the cabinet (function disabled)
Attention:
The cabinet is equipped with a
digital thermometer
positioned inside the display area, usually close
to the front glass.
The displayed temperature corresponds to the temperature in the refrigerated cabinet; there-
fore refer to this value for preserving the goods properly.
The temperature displayed by the controller corre-
sponds to the set point value. For technical reasons, the temperature values provided by the two displays (i.e. ther-
mometer in the refrigerated cabinet and controller display), even if related to one another, could be different and vary
during the cabinet’s operation. This fact is not an anomaly or a technical fault. To modify the working temperature, it is
necessary to consider the temperature displayed by the digital thermometer
inside the refrigerated cabinet
, and
then increase/decrease to the set point value memorized by the controller.
8.4 User interface
1
2
3
4
5
6
LED
MODE
Flashing
ON
Flashing
ON
ON
ON
Function
Compressor enabled
Compressor in waiting mode (delayed start)
Defrost in progress
Dripping phase in progress
Temperature alarm
Continuous cycle running
°C
ON
Measurement unit of temperature
°C
Flashing
Programming phase (for maintenance technicians only)
8. Dixell XR50CX control panel
Содержание Viessmann Tecto CI1 Series