AMP-43540
Description
Units
Specification
Supply Voltage
VDC
20-60
Maximum Input Power
W
960
Continuous Output Current per axis
Amps 8
Peak Output Current per axis
Amps 15
Amplifier Gain
A/V
0.4, 0.8 (default), 1.6
Switching Frequency
kHz
33
Brushless Motor Commutation angle
°
120
Supply Voltage Fuse
Amps
30
Fault Information
The AMP-43240 and AMP-43540 are protected from the following fault conditions.
Fault Condition
AMP-43540
AMP-43240
Over-Current Protection
yes
yes
Under-Voltage Protection
yes
yes
Over-Temperature Protection
yes
yes
Over-Voltage Protection
yes
yes
Hall Error Detection
yes
yes
The Over-Current protection circuit is shown in Figure 17. For further specifics on fault conditions,