The placement of ICM and AMP/SDM options is extremely important for 5-8 axis models. Reading left to right, the
first ICM (Axis 1-4) will be placed in the ICM (1) spot in Figure 1.2
and the second ICM (Axis 5-8) will be placed in
the ICM (2) spot. This also follows for AMP/SDM placement.
If the part number is not readily available, you can determine the information by using the 'ID' command. Issuing
an 'ID' command when connected to the controller will return your controller's internal hardware configuration.
WARNING
The CMB and ICM module options effect the pin-outs of the DMC-40x0.
Use Table 1.2 and Table 1.3 below to determine your CMB and ICM part numbers then refer to the
appropriate documentation for your pin-outs before connecting any hardware.
DMC, “DMC-40X0(Y)” Options
Option Type
Options
Brief Description
Documentation
X
1,2,3,4,5,6,7, and 8
Number of control axis
N/A
Y
DIN
DIN Rail Mount
DMC, “DMC-40X0(Y)” Controller Board
12V
Power Controller with 12 VDC
-16bit
16-bit analog inputs
4-20mA
4-20mA analog inputs
ISCNTL
Isolate Controller Power
TRES
Encoder terminating resistors
ETL
ETL certification
MO
Motor off jumper installed
Table 1.1: Controller board, DMC, “DMC-40X0(Y)” options
Chapter 1 Overview ▫ 3
DMC-40x0 User Manual
Figure 1.3: Layout of a complete DMC-40x0 part number