Options Ordered
Power Connector Locations
ISCNTL
AMP/SDM
Axis A-D
AMP/SDM
Axis E-H
ISAMP
Controller Power
(2-pin Molex on side)
AMP/SDM Power,
Axis A-D
(6- or 4-pin Molex)
AMP/SDM Power,
Axis E-H
(6- or 4-pin Molex)
X
X
X
X
X
X
X
X
X
X
1
X
1
X
X
X
X
X
1
X
1
X
X
X
X
X
X
X
X
X
X
X
X
Table 2.5: Available power connectors based upon option ordered
1
In this configuration the amplifiers are sharing power. Their bus voltages and grounds must be from the same source to prevent damage
to the controller and amplifiers.
NOTE
: If the 12V option is ordered, the DMC-40x0 is automatically upgraded to ISCNTL and should be powered
accordingly.
The DMC-40x0 power should never be plugged in HOT. Always power down the power supply before installing or
removing power connector(s) to/from controller.
NOTE:
Any emergency stop or disconnect switches should be installed on the AC input to the DC power supply.
Relays and/or other switches should not be installed on the DC line between the Galil and the Power supply. An
example system is shown in Figure 2.7 with a DMC-4080-C012-I000-I000-D3040-D3040:
The green power light indicator should go on when power is applied.
Step 5. Establish Communications with Galil Software
See Ethernet Configuration, pg 53 for details on using Ethernet with the DMC-40x0. To configure your NIC card
using Windows to connect to a DMC controller, see this two-minute video:
http://www.galilmc.com/learning/two-minute-display.php?video=connecting-to-ethernet-controller
For connecting using serial, see RS-232 Configuration, pg 51 for proper configuration of the Main DMC-40x0 serial
port.
Chapter 2 Getting Started ▫ 18
DMC-40x0 User Manual
Figure 2.7: Wiring for DMC-4080 with Amplifiers