![Galil Motion Control DMC-14 5 Series Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/galil-motion-control/dmc-14-5-series/dmc-14-5-series_manual_3258007048.webp)
Chapter 4 Communication
Introduction
The DMC-14XX has one RS232 port and one Ethernet port. The RS-232 port is the data set. The
Ethernet port is a 10Base-T link. The RS-232 is a standard serial link with communication baud rates
up to 19.2kbaud.
RS232 Port
The DMC-14XX has a single RS232 connection for sending and receiving commands from a PC or
other terminal. The pin-outs for the RS232 connection are as follows.
RS232 - Port 1
DATATERM
1 CTS – output
6 CTS – output
2 Transmit Data - output
7 RTS – input
3 Receive Data - input
8 CTS – output
4 RTS – input
9 No connect (Can connect to +5V or sample clock)
5 Ground
RS-232 Configuration
Configure your PC for 8-bit data, one start-bit, one stop-bit, full duplex and no parity. The baud rate
for the RS232 communication can be selected by selecting the proper jumper configuration on the
DMC-14XX according to the table below.
Baud Rate Selection
JUMPER SETTINGS
BAUD RATE
96 12
--
OFF OFF
19200
ON OFF
9600
OFF ON
1200
Handshaking Modes
The RS232 port is configured for hardware handshaking. In this mode, the RTS and CTS lines are
used. The CTS line will go high whenever the DMC-14XX is not ready to receive additional
characters. The RTS line will inhibit the DMC-14XX from sending additional characters. Note: The
DMC-14x5/6
Chapter 4 Communication
i
39
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com