Chepter 2: Operating the RRTU Programmer
There is a special programmer connected to the RRTU module for defining the number and
other settings of the RRTU.
CONNECTING THE HAND HELD PROGRAMMER REFERRED TO AS THE HHP.
•
Open the battery housing on the receiver module by removing the rubber plug from the
casing (Do not use any sharp instruments to achieve this).
•
Disconnect the battery from the Receiver module.
Receiver Module Version G3.1
– The HHP will be equipped with an interfacing harness
containing 4 wires namely Red (+), Black (-), White (Programming) and Purple (Programming).
•
Connect the red and black wires from the HHP to the battery connection of the Receiver
module.
•
Connect the white and purple wires of HHP to white and purple wires of Receiver
module.
Receiver Module Version G3.2
(March 2003) – The HHP will be equipped with an interfacing
harness containing 5 wires namely Red (+), Black (-), White (Programming), Purple (Programming)
and Green (Reset). The interfacing harness will also be equipped with a reset button.
•
Connect the red and black wires from the HHP to the battery connection of the Receiver
module.
•
Connect white, purple and green wire of HHP to the white, purple and green wires of the
Receiver module. The receiver module will be fitted with a Molex connector to prevent the
incorrect connection from takingplace.
GENERAL OPERATION OF THE HHP.
STEP 1
Press any key on the keypad to activate unit .The following will appear:
The software version previously programmed into the receiver module that is required to
operate the older receiver module (G2) or the newer receiver module (G3).
E.G. OLD =G2 Version of receiver module and NEW = G3 Version of receiver module.
The receiver modules address (I.D.) and the first output number of the receiver module as
previously programmed into the unit.
The number of outputs previously programmed into the receiver module.
E.G. A2 = 2 outputs or A3 = 3 outputs.
The maximum number of outputs the receiver module has been previously programmed to
handle. E.G. It will be either Max2 for a 2 line module or Max4 for a 4 line module.
NOTE!!!
This setting cannot be adjusted through the HHP and is set-up as a factory setting.
Appendix 2: Radio Remote Terminal Units (RRTU)
Содержание Galileo
Страница 1: ...GALILEO SETUP Hardware and Accessories Setup and Utility...
Страница 2: ......
Страница 11: ...11 Controller Hardware and Accessories Setup and Utility Hardware Description 2 2 1 4 The Power Supply...
Страница 24: ...24 Controller Hardware and Accessories Setup and Utility Galileo 32 board 2 Hardware Description...
Страница 66: ...AT1052...