background image

 

 

 

Installing the G2W System

 

Pre-Installation Planning 

Before installing the components of the Gal2Way system, make sure to examine the installation 
environment to determine the best locations for installation. 

You must make sure to install components above obstructions which may interfere with the RF 
transmissions between components. All components must be installed such that there is line-of-sight 
between all component antennas. 

 

Verify that there is a direct line-of-sight between the location of the unit’s antenna and the location 
of the concentrator’s antenna. 

 

Make sure that the distance between the field unit and the concentrator does not exceed 2 km. 

 

Field unit antennas are to be installed on poles which are not less than 2 m high. Verify that there are 
no obstructions which are more than 2 m high between the field unit and the concentrator. 

 

If there is a significant obstruction between a field unit and the concentrator and no better location 
can be found, you may be able to install a repeater (relay) to serve as an intermediary. 

For the repeater, you should find a location which has line-of-sight, without significant obstructions, 
and is within 2 km of both the concentrator and the field unit. 

 

Notes:

 

 

In order to achieve the maximum results with the fewest repeaters, place the repeaters 
in locations which support the maximum number of units. The system can support up to 
four repeaters. 

 

The system does not support chains of repeaters.

 

Installing the Concentrator 

The appropriate location for installing the concentrator is determined according to the communication 
type used: 

 

When direct communication (RS-232) is used, the installation should be next to the controller, at a 
distance of up to 10 m. 

 

When using an RS-485

 

adaptor, the installation can be 

further 

away, at a distance of up to 30 m. 

The concentrator should be positioned so that the communications and voltage cable will reach the 
controller. 

Affix the concentrator to the wall by inserting screws through the holes in the aluminum plate at the 
back of the box. 

Содержание Gal 2 Way

Страница 1: ...G2W Gal 2 Way Installation and Operation Instructions Version 1 0 July 2012...

Страница 2: ...nstallation process and operation protocols of the Gal2Way system Make sure to carefully read all of the information contained in this manual and keep this manual in a safe place for future reference...

Страница 3: ...g the Concentrator to the Controller via RS 232 Connections 21 Installing Field Units 21 Installing Repeaters 22 5 Performing Communications Diagnostics Tests 25 Performing the Communications Diagnost...

Страница 4: ...Battery Status 35 Testing Output Ports 36 Verifying the Connection to Discrete Input Devices 36 Viewing the Analog Input Device Signal Levels 36 8 Converting the Galileo Controller to the G2W System...

Страница 5: ...onents 13 Figure 5 Concentrator Buttons 15 Figure 6 Installing the Concentrator 20 Figure 7 Galcel to Adaptor Connection 21 Figure 8 Double Wire Cable Connections to Communication Adaptor 21 Figure 9...

Страница 6: ......

Страница 7: ...of products Technical Overview The G2W system consists of the following components Galileo Controller Concentrator Repeaters Field units The G2W system supports the following types of field units Gal...

Страница 8: ......

Страница 9: ...ious inputs of the field units to the controller Galileo controller Controls the irrigation system according to its programming and the field conditions Field Units The G2W system supports the followi...

Страница 10: ...put and output ports 4 8 x 18 V wire DC Latch output ports 6 x Discrete input ports 3 x Analog 4 20 mA 0 10 V input ports The analog input ports can operate at a voltage range of 0 10 V or a current r...

Страница 11: ...sted according to increasing communication transmission strength Single 916 CW HW antenna Two 916 CW HW antennas 916 CW HW antenna FG9023 antenna Two FG9023 antennas Repeater Relay The repeater unit i...

Страница 12: ...ions Connect the concentrator to two FG9023 antennas with RF cables Do not bend the cables below a radius of 30 cm Always keep 60 cm distances between antennas Concentrator Main Features Figure 3 Conc...

Страница 13: ...or Card Main Features Figure 4 Radio INT Card Components I LED indicators for normal card operation II LED indicators for communication with the CPU III LED indicators for communication with the conce...

Страница 14: ......

Страница 15: ...er unit downloads its default configuration settings from the default values defined in the concentrator You may want to modify these default settings in the concentrator before performing registratio...

Страница 16: ...on the screen The concentrator emits four beeps and returns to the main display screen 7 Perform a communications diagnostics test on the registered field units Refer to Performing Communications Dia...

Страница 17: ...r To view the list of registered field units and repeaters 1 Press until INSTALLER MENU is displayed on the screen and press to select it 2 Enter technician code 9999 The concentrator emits four beeps...

Страница 18: ......

Страница 19: ...nd the concentrator and no better location can be found you may be able to install a repeater relay to serve as an intermediary For the repeater you should find a location which has line of sight with...

Страница 20: ...re installing a DC or an AC unit DC operated Concentrator Connect a power supply of 12V DC to the correspondingly labeled connector AC operated Concentrator Connect the supplied power supply unit Note...

Страница 21: ...n of the signals to the concentrator even at a distance from the controller up to 30 m 3 Connect the double wire communication cable from the concentrator to the communication adaptor Connect the brow...

Страница 22: ...er using the supplied hanging accessories As an example the unit can be affixed to the lower part of the pole to which the antennas are attached Figure 10 2 Connect the antenna cable to the cable conn...

Страница 23: ...he unit box Affix on a metal pipe of 1 or 1 diameter using the supplied hanging accessories As an example the unit can be affixed to the lower part of the pole to which the antennas are attached 2 Con...

Страница 24: ......

Страница 25: ...confirmation Do not change the technician code 3 Press until DIAGNOSTICS is displayed on the screen and press to select it The WL DEVICES option is displayed on the screen 4 Press The TEST ALL DEVICES...

Страница 26: ...press to select it 5 Press to browse through the list of registered field units or repeaters of the type you selected until the field unit you want to test is displayed on the screen 6 Press The diagn...

Страница 27: ...Three red blinks means LOW communication strength or no communication strength at all Three orange blinks means MEDIUM communication strength Three green blinks means STRONG communication strength Per...

Страница 28: ...en a repeater is in use in the system the value displayed indicates the communication strength between the field unit and the repeater This feature is not enabled by default Enabling Communications St...

Страница 29: ...y Installation and Operation Guide 29 5 For the fourth input of each field unit define the following input settings In the Sensor Type row enter 0 10 V In the Min Value row enter 0 In the Max Value ro...

Страница 30: ......

Страница 31: ...t 0 7 For each input you can define the number of pulses with which a field unit sends status reports to the concentrator Default value 1 pulse Modifying the Default Field Unit Configuration Settings...

Страница 32: ...of the type you selected until the field unit you want to modify is displayed on the screen 7 Press The concentrator emits a beep and then the screen displays the unit s station number and the DEV SET...

Страница 33: ...type you selected until the field unit you want to modify is displayed on the screen 7 Press The message OFF to delete is displayed 8 Press to confirm the deletion The concentrator emits four beeps an...

Страница 34: ......

Страница 35: ...ield Units to a power supply the units signal to all their output ports to close Similarly when resetting Gal2Way 4 and Gal2Way 8 Field Units the units signal to all their output ports to close while...

Страница 36: ...word Discrete and above a number between 1 and 6 corresponding to each of the six ports Look for these indicators to verify connection to discrete input devices Viewing the Analog Input Device Signal...

Страница 37: ...corresponding concentrator in the Galileo controller To install a Radio INT adaptor card 1 Verify that the controller power supply is disconnected 2 Insert the Radio INT adaptor card AC0117 to the co...

Страница 38: ...al number of field units and repeaters both cable and radio that are to be registered in the system 5 Click the key symbol again for confirm the change Assigning Adaptor Card Slots for Field Units in...

Страница 39: ...example three field units which have four output ports each might require the selection of 1 2 3 4 and 5 6 5 In the Card Type of Units 01 64 row select Radio Two Directions If a second Radio INT adap...

Страница 40: ......

Страница 41: ...rom all persons FCC Compliance Statement This device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to...

Страница 42: ...not by Galcon including any misuse abuse of any Product or part s thereof and or any failure to install and or use any Product in full compliance with Galcon s instructions ii other systems components...

Страница 43: ...or any part thereof All of the above whether or not Galcon and or the Customer shall have been made aware of the possibility of such loss 10 In any event any liability which Galcon may have in connect...