G2W – Gal 2 Way – Installation and Operation Guide
17
c.
Repeat steps 1 through 3 to register an additional repeater unit.
Repeat these sub-steps until you have registered all the repeater units.
5.
After you have registered all the repeater units, press
to end the registration process and exit to
the main menu.
6.
Press
to confirm the registration. The message “DEV UPDATING”
is displayed on the screen.
The concentrator emits four beeps and returns to the main display screen.
7.
Perform a communications diagnostics test on the registered repeaters. Refer to
Communications Diagnostics Tests
on page 25.
Viewing the List of Registered Field Units and Repeaters
You can optionally view the list of field units and repeaters which are registered to the concentrator.
To view the list of registered field units and repeaters:
1.
Press
until “INSTALLER MENU” is displayed on the screen, and press
to select it.
2.
Enter technician code
9999
. The concentrator emits four beeps and requests confirmation. Do not
change the technician code.
3.
Press
until “DEVICES” is displayed on the screen, and press
to select it. The “MODIFY
DEVICES” option is displayed.
4.
Press
.
5.
Press
to browse through the list of field unit and repeater types. When the type you want to
view is displayed, press
to select it.
6.
Press
to browse through the list of registered field units or repeaters of the type you selected.
Optionally, press
for a displayed field unit or repeater to view detailed configuration
information about it, including the station number and Galileo controller ID number.
7.
Press
to exit to the main menu, and press
to confirm. The message “DEV UPDATING”
is
displayed on the screen. The concentrator emits four beeps and returns to the main display screen.