Please Note: the product should be installed before tiling is added to the bathroom wall.   
 
The electrical connection should be made via either a standard UK mains fused plug                                                                                                                                               
or fused spur. 
   
 
1. Initial fitting 
 
 
1.1

 

As per the drawing, use chisel to form a groove on the wall 50mm deep, 

      put in water pipe and line pipe (The dimensions shown are suggestions 
      and may vary for individual needs) 
 
 
1.2

 

As per the drawing, chisel another groove on the wall, 130mm wide, 

      130mm long, 50mm deep accommodate the cassette. 
 
 

2. Install the water pipe and the line pipe into the groove

 

   

2.1 As on the drawing, place the water pipe and the line pipe into the   
      Grooves created 
 
 
2.2 As per the drawing the connection for G1/2 should be sited external 

      to the wall ensuring that it is 50mm above the bathroom ceiling. 

   

2.3 Punch the hole of the cassette on the left side using a screwdriver,   

      then place the cassette into the groove. Secure the cassette with   

      adhesive and ensure the line pipe is connected with the cassette.   

 

2.4 Apply tiles and grout to the wall remembering to keep a suitable area                                                                                                                                                                                                                                                                                                                                                     
place for the G1/2 and cassette.   

 

 

 

 

 

Содержание GRS1

Страница 1: ...nd flow rate The light buttons on the panel indicate water temperature with different colours to avoid accidental scalding Working conditions Incoming mains temperature of cold water is 4 C 29 C Outgoing hot water temperature range is 55 C 85 C 55 C 65 C is recommended The initial mixer temperature is factory set at 38 The processor must be earthed to prevent leakage Before using of this product m...

Страница 2: ...m wide 130mm long 50mm deep accommodate the cassette 2 Install the water pipe and the line pipe into the groove 2 1 As on the drawing place the water pipe and the line pipe into the Grooves created 2 2 As per the drawing the connection for G1 2 should be sited external to the wall ensuring that it is 50mm above the bathroom ceiling 2 3 Punch the hole of the cassette on the left side using a screwd...

Страница 3: ...3 Install Riser Rail ...

Страница 4: ...aled to avoid leakage MAINTENANCE Keep the product clean by washing with warm water and mild detergent regularly 6 Attach the overhead shower head 7 Install the processor and control 7 1 As per the drawing below connect up the water pipe s 7 2 Pull the data wire through the water pipe and connect up the processor and controller ...

Страница 5: ...ndicator until the minimum flow rate is reached Flow rate increase with each touch on the button there is an audible signal the flow rate will increase by one step and the flow rate column will reduce one line on the LCD indicator until the maximum flow rate is reached Rain Shower Standard Shower Switch with each touch on the button there is an audible signal and the water flow will switch between...

Страница 6: ... the On Off Pause button briefly will pause the flow holding longer than 2 seconds will turn the appliance OFF 11 Pairing the Start stop hand held remote control With the shower off press and hold the Temperature increase button on the circular control panel the display will flash blue Still holding the Temperature increase button press and hold the Start Stop button on the hand held remote for 2 ...

Отзывы: