background image

G8-09-11-2018 

Limit Switch Setup for NC-G8 and above controllers. 

1.

 

The limit switch wires from 

the control board come tied 

together, this bypasses the 

limits. At this stage the lift will 

not stop automatically, you 

will have to stop the lift with 

the remote, gel pad or by 

killing power. Verify that the 

lift does indeed go up and 

down with the remote and 

gel pad.  On a 2-stop these are 

the three wires (five for 3-

stop) with wire nuts coming off the control board. 

Separate these wires. Then, connect these wires to 

your limit switch cord, color to color. The necessary 

blue wire nuts will be in the bag with the control box 

mounting hardware. 

a.

 

Red: Limit for the top stop. When disconnected from the 

black wire, the lift will not go up. 

b.

 

Green: Limit for the bottom stop. When disconnected 

from the black wire, the lift will not go down. 

c.

 

Black: Common signal wire. When disconnected, the lift 

will not move. 

d.

 

Blue: (3-stop only) Middle limit going up. To set you must 

be sending the lift from the bottom limit after each 

adjustment. 

e.

 

White: (3-stop only) Middle limit going down. To set you 

must be sending the lift from the top limit after each 

adjustment.  

2.

 

Remove the cover of the limit switch by loosening the four large 

screws.  

 

 

 

Содержание Gel Pad

Страница 1: ...G8 2 23 1 Control Box Wiring Programming Guide...

Страница 2: ...r for your lift Here you can turn your unit off and on send the unit to its levels or stop travel in any direction The remotes are also programmed from the Gel Pad On 2 stop lifts or lifts for marine...

Страница 3: ...during this process Please read through instructions thoroughly before starting The control board will exit the programming mode after 7 seconds of inactivity you may have to practice the steps a few...

Страница 4: ...the green LED beside the button lights up approximately 3 seconds 3 Press either the up or down button on your remote you will see a corresponding flash from the learn LED o Additional Remotes Repeat...

Страница 5: ...trician or contact our office Galaxy Unlimited LLC is not responsible for incorrect field wiring damages to equipment or harm to anyone or anything Incorrect field wiring will void warranty Motor Wiri...

Страница 6: ...r contact our office Galaxy Unlimited LLC is not responsible for incorrect field wiring damages to equipment or harm to anyone or anything Incorrect field wiring will void warranty Motor Wiring Black...

Страница 7: ...s to your limit switch cord color to color The necessary blue wire nuts will be in the bag with the control box mounting hardware a Red Limit for the top stop When disconnected from the black wire the...

Страница 8: ...op and bottom limits will hit on opposite sides of their microswitches based on cam rotation d 1 8th turn on the adjustment screw is about 6 8 inches of travel e On each test of adjustment run the lif...

Страница 9: ...a cam per interlock is used aside from special cases Typically a white wire for the first interlock if 3 stop red with black stripe then blue if there is a second interlock if 3 stop red with black st...

Страница 10: ...ed Downstairs application Black Not Used White Not Used 5 Route all wires and tuck the circuit board back in its place 6 Reinstall Gel Pad Route the ribbon cable so that it does not kink sharply 7 Rec...

Страница 11: ...cker approximately 6 from the edge of the unit on the subfloor beams Then you will drill an 11 16 hole in the beam and install the cable gland as shown Next route travel wire from the switches through...

Страница 12: ...Serial Number of Unit Clear and specific description of the defect Ship malfunctioning Remote Control Box to above address for confirmation evaluation at the expense of the customer This limited warra...

Отзывы: