10
G8-09-11-2018
**
Additional Equipment Setup Section (Not Standard) **
Call Station
1)
Disconnect service of the 110vac or 220vac to the Galaxy control
box.
2)
Remove the Gel Pad and then carefully unplug the ribbon cable
from the circuit board.
3)
Untuck the circuit board from the top of the box and observe the
blue screw terminals located near the Gel Pad connector.
4)
Connect the wires from the call station in the following pattern
starting with the terminal closest to the Gel Pad connector.
o
Call/Send Station (2 button):
Upstairs application: Black, Red, Green, White
Downstairs application: Black, Green, Red, White
o
Call Station (1 button):
Upstairs application: Black, White, Not-Used,
Not-Used
Downstairs application: Black, Not-Used, White,
Not-Used
5)
Route all wires and tuck the circuit board back in its place.
6)
Reinstall Gel Pad. Route the ribbon cable so that it does not kink
sharply.
7)
Reconnect power to the Galaxy control box and test!
Interlock
The Interlock is installed at the deck gates or doors to prevent them from
opening when the basket is not present. It will come with a latch, a bypass
key, and a length of cord. The unit will not have power until the interlock
is installed and working correctly. The terminals on each interlock are
painted to correspond to the wire colors in the cord. The other end of the
cord will simply plug into the box. To control when the interlock unlocks
you will match the cam adjustment at the limit switch for the white
(typically) wire so that corresponds to the stop limit setting of the floor
that the interlock is installed on.