GB1200 User Manual
- -
10
Correcting method as follows:
1. First press the keys R & START, the display board
displays “CAL”--“CAL”. Indicator LEDs of phase position
blink, release the keys after indicator LEDs go out.
Left Window Right Window
Fig.1
2. Continuously press the keys , and F of distance
▽ △
dimension A, shown in Fig.2, if the value displayed is not
correct, press the keys and of width dimension L
△
▽
to
adjust.
Fig.2 Standard Memory
Correcting the degree of accuracy of value
3. Press the key of distance dimension A, as Fig.3
△
shown, which is that adjusting static balancing parameters.
When offset data are too many, adjust to shown in Fig.3.
Fig.3 Standard Memory
Correcting value 100g of inner of static balancing
4. Then press the key , as Fig.4 shown, if the value
△
displayed is not correct, press the keys and of
△
▽
width dimension L and adjust.
Fig.4 Standard Memory
Correcting the error of degree
5. Return by pressing the key of distance dimension A.
△
6. After correcting, self-calibrate again, see 5.1, or else correct ineffectively.
5.3 Trouble shooting
Troubles Reasons
Solutions
Do not display after starting.
1. Check outer circuit.
2. Check whether the
switch is damaged.
3. Main board and
power panel are
damaged.
1. Check it with multimeter.
2. Replace it.
3. Replace it.
Display after starting but do
not work and buzz, display
Err1.
Capacitor of motor did
not work.
Replace a 20UF/400V
capacitor.
1. Display Err1 and do not 1. Starting delay is 1. Replace delay or power