TO STOP THE SHOWER 

 

Press Button ‘C’ to Stop the shower (fig.13). 

 

Water will cease to flow.  

 

Switch off the electricity 
at the ceiling switch or 
local isolator. 

 

3500M Models 

Please note that the                                                       

water will continue to                                                        

flow for around six  

seconds to cool the  

shower for the next user. 

 

Once a temperature setting to your liking has 
been achieved, Knob ‘B’ will rarely need 
adjusting.                                                               

You must however take into account required 
adjustments for variations of incoming mains 
water temperature between summer and winter 

(see ‘Advice to users’ on page.2).

 

 

The ‘Eco’ setting of Knob ‘A’ reduces the power 
used by the shower giving a cooler shower or 
the option of reduced water flow.                                                                                       

This option is mainly for summer usage and if 
this is used then Knob ‘B’, must be re-adjusted. 

 

The ‘Cold’ setting of Knob ‘A’ will supply water 
without any heating.  

 

During normal operation, if an overheated water 

temperature is sensed then the heater will switch 
off.  
Water will continue to flow and cool down before 
the heater switches back on again. 

Note: The shower may run hot then cold at the 
start of a showering session if the shower has 
recently been used.       

                                           

 

ADJUSTING THE SHOWER HANDSET  

 

To enhance your shower experience your shower 

has a multi-spray pattern handset and these 
patterns can be adjusted by simply rotating the 
sprayplate. 

Each mode is identified by an audible click. 

 

WARNING: 
DO NOT SWITCH THE SHOWER ON 
IF YOU SUSPECT IT OF BEING 
FROZEN.  WAIT UNTIL YOU ARE 
SURE IT HAS THAWED OUT. 

 

WARNING: 
DO NOT OPERATE THE SHOWER IF 
WATER IS DISCHARGED FROM THE 
PRESSURE RELIEF VALVE.                                         
MAINTENANCE IS REQUIRED 
BEFORE IT CAN BE USED AGAIN. 

 

 
WARNING:                                              
CONSIDERATION SHOULD BE 
GIVEN TO SUPERVISING THE 
YOUNG, ELDERLY AND THE INFIRM 
WHILST THEY USE THIS SHOWER. 

 

 

 

 

 

We offer a technical advisory service on the 

telephone to installers and other customers with 
problems in the field.

 

 

Please call our technical team on:  

 

0844 372 7766 

 

Or alternatively email us on: 

 

[email protected] 

 

Remember to quote the exact type of shower,                                             
as written on the front of the shower and on this 
leaflet.                                                                
The model and serial number are located on the 

bottom face of the shower. 
Make a note of those numbers here, and be sure 
to quote them if you call for advice.  

 

Model Number: 5356 

. . . . . . . . . . . . . . . . . . . . . . . .

   

 

Serial Number: 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

     

 

NOTE: You may be charged for a service 

call if you do not have the serial number. 

 

 

 

13 

 

Turn off electricity 
supply to shower at 
local isolator. 

Содержание 3000M

Страница 1: ...IMPORTANT This booklet should be left with the user after installation and demonstration Installation and User Guide 3000M 3500M 3500Msi White and Chrome Models SMART ELECTRIC SHOWERS...

Страница 2: ...unting into steam rooms or steam cubicles Isolate the mains electrical and water supply before removing the appliance front cover DO NOT fit any sort of tap or control on the appliance outlet The appl...

Страница 3: ...a FIXING THE SHOWER TO THE WALL 1 Position the riser rail at a convenient height for majority of users fig 1 and mark its position For accessory details see fig 9 for White Models or see Sheet provide...

Страница 4: ...minimum flow rate of 8 litres minute The maximum static pressure must be no greater than 1000kPa 10 bar 150 psi Minimum running pressure must be obtained at 9 litres minute for 9 5kW WARNING BEFORE C...

Страница 5: ...shower Blockage in the water ways particularly the handset and inlet filter will prevent the heater working properly Note You may be charged for a service call if it is due to incorrect installation 5...

Страница 6: ...71 WARNING FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN FAILURE OF THE TERMINAL BLOCK WARNING THE UNUSED SUPPLY TERMINAL BLOCK MUST NOT BE USED FOR ANY OTHER PURPOSE 5 Refit the detachabl...

Страница 7: ...7 9 White Models See sheet provided for Chrome Models...

Страница 8: ...on to the unit Your shower has 2 control knobs and a push button fig 12 Knob A controls the power selection High Full power Eco Half power Cold No heat Knob B controls the temperature of the water But...

Страница 9: ...shower has recently been used ADJUSTING THE SHOWER HANDSET To enhance your shower experience your shower has a multi spray pattern handset and these patterns can be adjusted by simply rotating the sp...

Страница 10: ...Y 2 YEARS WITH OUR APPROVED PART WARNING IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER YOU MUST CLEAN THE SHOWER HANDSET REGULARLY CLEANING THE FILTER The filter can be cleaned in order to maint...

Страница 11: ...n the 3500M Model The shower includes a shutdown feature that means water will continue to flow for around 6 seconds after Button C is pressed Broken parts Please contact our after sales service depar...

Страница 12: ...ncoming Water Temperature Changes The required water temperature is achieved by adjusting the rate of water flow The diagram shows the principle involved in relating temperature rise to flow rate The...

Страница 13: ...Solenoid Valve f Pressure Switch g Terminal Block x 2 h Detachable Backplate Section i Water Inlet j Water Outlet k Wall Fixing Key Hole Slot l Alternative key Hole slot m Wall Fixing Slot n Relay 350...

Страница 14: ...5 WRAS Water Isolating Valve Cat No 93793757 All Chrome Flexi Fit Accessories Kit Cat No 83595345 White Chrome Flexi Fit Accessories Kit Cat No 83595344 White Chrome Premium Accessories Kit Cat No 83...

Страница 15: ...PLEASE SEE BELOW AND DETAIL ON PAGE 6 Ensure power select Knob is aligned to the cold graphic 9 o clock position whilst the Flat in the product is aligned as shown figs 7 Ensure temperature Knob is al...

Страница 16: ...guarantee has no effect on the expiry date The guarantee on any exchanged parts or product ends when the original guarantee period ends EXCLUSIONS This guarantee DOES NOT cover damage or defects aris...

Отзывы: