![Galanz XQG90-T514VE Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/galanz/xqg90-t514ve/xqg90-t514ve_service-manual_3247248030.webp)
XYJGT90100TVE-001
29
E07
水加热温度
传感器故障
There is a
temperature
sensor fault
水加热温度传感
器电压值范围异
常(短路或断路)
Abnormal voltage
range of water
heating
temperature
sensor (short
circuit or open
circuit)
1
、水加热温
度传感器线
束端子松动
或线束故障
1. The
connection
between the
wire and
temperature
sensor is not
secure or
wire is
damaged
1
、检查线束端子
插接是否牢固或
更换线束
1. Check the
connection and
ensure it is
secure or change
wire
跳过加热阶
段,程序结
束后报警
Skip the
heating
phase,
alarm after
the end of
the
program
关闭
电源
Turn
off the
power
2
、温度传感
器故障
2. The
temperature
sensor is
damaged
2
、更换温度传感
器
2. Change the
temperature
sensor
3
、电脑板故
障
3. The PCB
is damaged
3
、更换电脑板
3. Change the
PCB
E09
通讯故障
Inverter fails
to start
1
、设定时间无应
答
1.No response for
setting time
2
、设定次数应答
错误
2.Answer error
for setting times
1
、接线端子
未插好或线
束故障
1. The
connection
between the
wire and
inverter is
not secure
or wire is
damaged
1
、检查线束端子
插接是否牢固或
更换线束
1. Check the
connection and
ensure it is
secure or change
wire
闭合门锁,
关闭所有负
载,排水至
安全水位后
再持续排设
定时间
Close the
door lock,
close all
loads, and
drain for
setting
time after
draining to
the safe
water level
关闭
电源
Turn
off the
power
2
、电脑板或
变频板故障
2. The PCB
or inverter is
damaged
2
、更换电脑板或
变频板
2. Change the
PCB or the
inverter board