XYJGT90100TVE-001
25
E04
溢水报警
Water
overflows
the machine
筒内水位超高(水
位开关检测到溢
水水位)
The water level in
the cylinder is too
high (the water
level sensor
detects the
overflow water
level)
1
、进水阀故
障
1.The water
valve is
damaged
1
、更换进水阀
1. Change the
water valve
1
、闭合门
锁,关闭所
有负载,排
水至空筒水
位后再持续
排设定时
间;
1.Close the
door lock,
close all
loads,
drain to the
empty
cylinder
water level
for setting
time
2
、关闭排水
泵,保持水
位检测;当
再次检测到
溢出水位,
重复上述过
程
2. Close
the drain
pump to
maintain
the water
level
detection;
when the
overflow
level is
detected
again,
repeat the
above
process.
关闭
电源
Turn
off the
power
2
、水位开关
或线束故障
(溢水水位
短路)
2. The water
level sensor
or wire is
damaged
(overflow
water level
short circuit)
2
、检查水位开关
及线束
2. Check the
water level
sensor and wire
3
、电脑板故
障(进水阀可
控硅短路)
3. The PCB
is damaged
(thyristor
short circuit
of water
valve)
3
、更换电脑板
3. Change the
PCB