Smart 400 TIG Pulse
25
3.2.1 POWER SOURCE PANEL FUNCTION DETAILS
Figure 3-4 Welding mode selection zone
Welding mode selection zone contains welding mode
indicators and selection key.
Welding modes include DC TIG, Pulse TIG, DIC MMA
(TIG400 has no pulse TIG function). Press the welding
mode selection key to choose the according welding
mode. The welding mode being selected is the
according mode with its indicator lighting up.
Remark: welding mode indicator will light up during
welding processing (when there is welding current).
Figure 3-5 TIG selection zone
This zone include 3 parts: TIG operating mode
selection, water cooling switch key, arc ignition switch
key (HF& contact)
1. TIG welding modes: 2T
、
4T
、
REPEAT
、
SPOT
,
Press
to select the according welding mode.
2.TIG water cooling witch key
(
1
)
press the key and indictor is on to enter water
cooling mode. In full set welding system, water tank
will give water flow signal and check whether there is
a water-lack; there is E-5 warning and is with no
output in case of water lack; please check if
everything is back to normal and observe whether
there is E-5 when under TIG.
(
2
)
Every time operator presses this key, the gas
valve will work. Therefore, it can be used as gas
detection.
3. Arc ignition type selection.
(
1
)
press this key and indicator is on to enter HF arc
ignition.
(
2
)
press this key and indicator is off to enter lift arc
ignition. When under this mode, put the torch to
contact workpiece; pull torch trigger then lift the torch
slowly to achieve arc ignition.
Remark: not available for MMA
Figure 3-6 MMA parameters selection zone
This zone contains parameters selection and VRD
switch-over
1.Press to switch MMA parameters; it can be
circulated among HOT START
、
CURRENT
、
ARC
FORCE
2. Press VRD and indicator is on; MMA will enter VRD
mode and OCV is 19V.
Remark: not available for TIG and TIGP.
Figure 3-7 TIG parameters selection zone
1. Press to circulate clockwise and select the
according TIG parameter.
2. Parameter description:
T
pre
—Pre-flow time I
s
—Initial current
T
up
—Up-slope time I
p
—Peak current
I
b
—Base current T
down
—Down-slope time
I
f
—Final current T
post
—Post-flow time
Hz—Pulse frequency %--Pulse duty factor
T
spot
—Spot welding time
Remark: there is no I
b
、
Hz
、
% when under TIG and I
p
is welding current.