Talano & Alera Installation v2.6
8
Fitting Instructions
7)
Plumbing.
Connect feeds to the pre-fitted bathroom plumbing as per the pre-installation
document. Ensure that the plumbing feeds are in the correct orientation. The TMV heads should
point towards the head end of the bath. Quality check for leaks, water temperature and correct bath
operation. If the water temperature needs alteration, access the TMV and adjust as per the
manufacturer’s instructions.
See Addendum at back of this pack for TMV setting.
Note
: If connected to a facility that has pre-
set ‘blended’ water supply then the TMV’s will not be
required. Check with the owner of the property to ensure that the temperature of the blended water
supply is no more than 43 degrees.
8)
Make a permanent electrical
connection following current IET regulations. Secure the cable
with conduit if required for cable protection. Ensure that the bath is fully earthed. Where a Spa is
fitted a 13 Amp IP65 rated switched fused spur is also required. Where applicable, junction boxes
should be fitted underneath the bath and affixed using a mechanical tool (screw or similar). Ensure
that a suitable location is chosen i.e. positioned off the floor, and behind bath panels.
A 30mA RCCD or RCBO is required in compliance in accordance with current Edition IET
regulations. This should be located outside the bathroom or on the consumer unit covering that
area of the building. Earth Bonding and Cross Bonding are to be fitted and tested for continuity in
accordance with IET regulations. The trailing flex should be protected by use of protective conduit.
Figure 6.0
The Spur box should be mounted between 300-500mm off the floor .
9)
Fasten the chrome handset holder
in place onto the side of the bath. Pre-drilled holes and
fixings are provided.
10)
Plug in the handset
. Offer up the handset connector to the front panel and fasten into place on
the front panel. Remove the plastic circlip from socket blanking plug next to the power supply on the
control box. Fit the handset Jack into the socket connector. Fit the circlip into place around Jack
ensuring that the two lugs locate correctly. There is a cable tie on the inside of the panel where
spare wire can be looped.