background image

Talano & Alera Installation v2.6 

Fitting Instructions

 

 

  

 

11) Offer up the side panel to the front of the bath. Guide it under the lip of the bath shell and then 
mark the floor along the front of the panel to allow a wood batten  (800mm x 25mm x 25mm) to be 
fixed to the floor midway along the panel. This will prevent the panel moving at the base. Repeat as 
required for other panels.  
 
(End panel batten dimensions - 600mm x 25mm x 25mm)   
 
Remove the panels and fix the wooded battens to floor 

– Take care to allow for the thickness of the 

panel. Fix the batten 4mm in from the marked line to allow for panel thickness. Once fitted the side 
panel can be clipped into position. Further work may be required before the end panels can be 
fitted (see step 12). 

Figure 7.0  

 

Affix wooden battens to the floor to prevent the panel moving at the base. 

 

12) 

End Panels 

may require trimming depending on the panel configuration: 

 

One Side panel and one End 

– Trim end panel on the ‘wall side’

 

Two Side panels and one End panel  - No trimming required

 

Two Side panels and two End panels  - No trimming required 

 

Where is trimming is required the trim should take place at the start of the ‘radius’ of the panel.  We 
recommend a wall batten is fitted in a similar manner to the floor battens. 

 

13) 

Offer up panels into place 

and screw to battens and wall as needed. 

 

14) 

Attach labels as required 

and fully test sequence prior to handover.

 

      

 

Содержание TALANO

Страница 1: ...lation v2 6 Gainsborough Bathrooms Gainsborough House Brickyard Road Aldridge WS9 8SR United Kingdom Tel 44 0 1527 400022 email service gainsboroughbaths com www gainsboroughbaths com TALANO ALERA INS...

Страница 2: ...ll floor finishes should be in place prior to installation i e Altro Tiling Items supplied with the Bath Installation manual User manual Bath unit bath shell support frame control pack Bath surround p...

Страница 3: ...th to floor Feet frames MUST be level and vertical Use a spirit level Utilise shims if required Connect bath to temporary power supply Connect handset and power up bath Place bath into position Connec...

Страница 4: ...acity 230 200 litres Approximate Bath Weight Empty 119Kg 115Kg Power Supply Mains 230V to be supplied via 30mA RCD Operating Voltage 24V Battery Backup Yes Water Supply Hot Cold water at 1 bar minimum...

Страница 5: ...ximum Water Capacity 230 200 litres Approximate Bath Weight Empty 130Kg 125Kg Power Supply Mains 230V to be supplied via 30mA RCD Operating Voltage 24V Battery Backup Yes Water Supply Hot Cold water a...

Страница 6: ...cing see figure 4 0 for further details 2 Offer the bath into position making sure that the floor is of a sound solid surface If the floor slopes i e wet room installation with a centre drain shims sh...

Страница 7: ...Wood Floorboard M10 x 50 Nylon Plug Type E 4 M8 Form C Washer BZP 4 Figure 5 1 4 With the bath in position mark the floor where it is to be drilled See Figures 4 1 4 2 for dimensional information A T...

Страница 8: ...plicable junction boxes should be fitted underneath the bath and affixed using a mechanical tool screw or similar Ensure that a suitable location is chosen i e positioned off the floor and behind bath...

Страница 9: ...thickness Once fitted the side panel can be clipped into position Further work may be required before the end panels can be fitted see step 12 Figure 7 0 Affix wooden battens to the floor to prevent...

Страница 10: ...on Addendum Head End Base Plate Figure 7 0 Please take note of the floor fixing locations illustrated on the base plate diagram Precautions should be taken to investigate floor integrity paying partic...

Страница 11: ...Talano Alera Installation v2 6 11 Installation Addendum...

Страница 12: ...Talano Alera Installation v2 6 12 Installation Addendum...

Страница 13: ...the bath and will then stop Press Seat out which will bring the seat down and out do not use until the fault is rectified Once power is restored allow the batteries to recharge before operation usuall...

Отзывы: