Pub. 42004-550C
Elemec3
Console Manual
—Version 3
Page 68 of 109
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-550C.docx
07/21
Zone Builder
Use the
Z
ONE
B
UILDER
screen to configure zones in an
Elemec3
system. The
Z
ONE
B
UILDER
screen
opens when creating a new zone or when selecting an existing zone from the
Z
ONE
L
IST
on the
Z
ONES
screen. Make zone changes by highlighting the zone in the
A
VAILABLE
D
ESTINATIONS
pane and clicking
the
E
DIT
Z
ONE
button.
Figure 75. Zone Builder
Zone Description—
unique descriptive name of the zone.
Send Zone Audio to Event Recorder
—records all audio for this zone in the event recorder. Enable this
option on the
S
YSTEM
P
ROPERTIES
screen (see the Globals section) to enable the option here.
Beneath the
Z
ONE
D
ESCRIPTION
field are four selectable audio outputs. Select the audio outputs to
include in the zone. The available audio outputs are:
•
Include Page/Party Output
—includes Page/Party output. Enable the Page/Party audio source under
the
S
OURCES
E
NABLED
section of the
A
UDIO
I
NPUTS
tab (see the Sources Enabled section) to enable
this option.
•
Include Monitor Output
—includes the monitor output and the IP monitor out, if configured.
Enabling insert two on the
G
LOBALS
pane on the
S
YSTEM
P
ROPERTIES
screen (see the Globals
section) disables this option.
•
Include Aux Output
—sends all audio for this zone to the auxiliary output. Enabling insert one on
the
G
LOBALS
pane on the
S
YSTEM
P
ROPERTIES
screen (see the Globals section) disables this option.
•
Include IP Aux Output
—sends audio for this zone to the IP auxiliary output.