Miscellaneous Pane
Figure 115. Miscellaneous Parameters Pane
Diagnostics
—determines what the station tests each time the diagnostic self- test runs. Set this to
HANDSET
+
HEADSET
+
SPEAKER
to execute all diagnostics, any combination of the three, or OFF.
Valid settings: OFF, HANDSET, H HEADSET, SPEAKER,
H SPEAKER
,
H SPEAKER, H H SPEAKER.
LED Triggering Parameters
LED1–LED5
—Configure each LED to turn on during various station conditions (see the I/O States
section).
Other
E-Z All Call
—only valid on handset stations equipped with an
A
LL
C
ALL
paging pushbutton. This
parameter determines whether an operator must press the handset pressbar when making a page to the
PAGETX_B_SOCK
multicast socket. Valid values are:
•
TRUE—Only press the
A
LL
C
ALL
button after lifting the handset to start paging to the
PAGETX_B_SOCK
multicast address. Do not press the handset pressbar to initiate the page.
Pressing the handset pressbar without holding the
A
LL
C
ALL
button initiates a page on
PAGETX_A_SOCK
.
•
FALSE
—The operator must always press the handset pressbar to make a page; including the use
of the
A
LL
C
ALL
button.
N
OTE
:
Do not set this parameter to TRUE on stations that do not have an
A
LL
C
ALL
button.
Hookswitch Invert
—This parameter enables the inversion of the current physical state of the hook-
switch represented by the ON-HOOK and OFF_HOOK variables. Valid settings are:
•
TRUE—ON-HOOK and OFF-HOOK values are reversed.
•
FALSE
—ON-HOOK and OFF-HOOK values are represent the actual current state of the
handset.
Handset Timeout
—limits the period that a station is off hook (in minutes with a default of eight
minutes). A setting of zero disables the hookswitch timeout.
Pressbar Timeout
—limits the period that a page can continue (in minutes with a default timeout of two
minutes). A setting of zero disables the pressbar timeout.
E3 Fault Reporting
RTU Fault Mode
—specifies the reporting level the system uses to report RTU-related faults.