Access Panel Properties
Select an access panel from the
A
CCESS
P
ANEL
I
NTERFACES
S
UMMARY
screen.
The
A
CCESS
P
ANEL
P
ROPERTIES
dialog
box opens:
Description
—unique description for the
access panel.
Intrinsically Safe?
—configures the access
panel as intrinsically safe.
Local Cancel Only?
—only allows
cancelling events initiated at this access
panel.
Local Ack Only?
—only allows
acknowledging events initiated at this
access panel.
Audio Path
—audio path assigned to the
current access panel.
This automatically assigned value is
changeable for access panels connected to an API type II card. Editing this property while the
selected audio path is in use causes the current access panel to swap audio path values with the other
panel. Audio path assignments of access panels connected to an API type I cards are set by the
system.
Location
—the physical location of the access panel (see the Locations section).
Volume Level
—sets the microphone volume level for the access panel.
Supervision—
•
Normal—a continuously supervised always-present access panel.
•
When Present—an access panel supervised only when present. (Specify an input contact to
notify the system when the panel is present and must be supervised.)
•
Unsupervised—an unsupervised access panel.
Address
—of the access panel. This setting must match the physical address configured on the access
panel.
Max Duration (*Global setting for all panels)
—maximum duration of a live page for all access panels.
Button Lockout (*Global setting for all panels)
—the period after the maximum duration elapses before
reporting a stuck button fault and a panel lockout occurs.
Figure 33. Access Panel Properties