Auteldac 4
9
The telephone is supplied suitable for wall mounting and desk
mounting.
IMPORTANT WARNING - Gland Specifications
Glands are not supplied. All glands and cables should comply with IP54
or better to meet ‘Increased Safety’ (‘e’ type) requirements. Only ‘e’ type
glands and suitable cables should be used and must be fitted correctly.
Note that the environmental rating of the telephone will not exceed that
of the glands, i.e. in order to maintain an IP66 rating, glands must also
meet IP66.
ALL POSSIBLE MEASURES MUST BE TAKEN TO ENSURE
WATER, FLUID OR DUST DOES NOT CONTAMINATE THE
INTERNAL COMPONENTS OF THE TELEPHONE WHILST
UNPACKING, PREPARING AND INSTALLING IT IN INCLEMENT
WEATHER CONDITIONS OR BY NEGLIGENCE.
FAILURE TO TAKE THIS PRECAUTION WILL INVALIDATE YOUR
WARRANTY AND CERTIFICATION
The telephone body must
NOT
be opened, nor glands removed or
cables disconnected unless all supplies to the telephone, including
telephone cables and external devices have been isolated outside the
hazardous area. Terminals for incoming cables are ‘e’ type and must be
carefully connected so as to make an ‘e’ type termination.
The Code of Practice for ‘e’ type enclosures is specified in EN60079-14.
The installer and all service personnel should be familiar with the
relevant sections of these documents.
If only one gland entry is used, the sealing plug fitted to the second
gland position should be left in place.
2.2 Protection Against Hazards
The Auteldac 4 telephone has been designed such that it does:-
-
Not give rise to Physical injury or harm due to contact.
-
Not produce excessive surface temperature, infra-red,
electromagnetic or ionising radiation.
-
Not have non-electrical dangers.
Note:- The above only applies provided the instructions, restrictions and
warnings provided in this manual are complied with.