background image

Auteldac 4 

 

13

5.  Re-tighten the straps firmly and trim off any excess band material. 

For security the driving head of the band may also be sawn off. 

2.6  Desk Mounting / Rake 

IMPORTANT WARNING:- Risk of impact or falling 

This telephone, when used in a desk mounting mode, should be located 
on a horizontal, flat non-slip surface. Due to the heavy and robust 
construction of the unit, users must take care when using the handset 
or headset, not to pull the cord to such an extent as to cause the 
telephone to be pulled off the flat surface, and possibly cause damage 
or injury to persons or equipment. Therefore it is recommended that the 
unit be fixed in position using fixing positions and method detailed in 
section 2.4 if there is any risk of the unit being dislodged as described 
above. 

To provide a 'rake' for convenient operation, the Front Casing may be 
turned through 180° before it is fitted to the Rear Casing. Thus the 
cable entries are at the rear of the telephone. 

1.  Ensure that the supplied rubber feet are fitted to the underside of the 

Rear Casing if the telephone if not fixed into position. 

2.  Rotate the Front Casing through180° and fold the keypad ribbon 

cable to ensure that it lays flat against the potted block when re-
assembled.  Refer to Figure 9 - Ribbon cable positions (page 21) 

3.  Continue the installation procedure with the connection of individual 

wires from the cable as described in sections 2.7 onwards.

 

 

 

Figure 4 - 

Providing the rake

 

Содержание Auteldac 4

Страница 1: ...Installation and User Guide Auteldac 4 ATEX IEC Ex Approved Hazardous Area Telephone GAI TRONICS A Division of Hubbell Ltd...

Страница 2: ...inst Hazards 9 2 3 Preparation 10 2 4 Wall Mounting 11 2 5 Pole side Mounting 12 2 6 Desk Mounting Rake 13 2 7 Connections and Cabling 14 2 8 Option Settings 18 2 9 Assembly of Telephone on to Install...

Страница 3: ...NATE THE INTERNAL COMPONENTS OF THIS TELEPHONE WHILST UNPACKING PREPARING AND INSTALLING IT IN INCLEMENT WEATHER CONDITIONS OR BY NEGLIGENCE FAILURE TO CARRY OUT THIS PRECAUTION WILL INVALIDATE CERTIF...

Страница 4: ...h dial memories 18 button version only Hearing aid compatible inductive coupling as standard Available in a range of keypad options including CB Headset option available 1 2 External Signalling The Au...

Страница 5: ...8 001 The holes are arranged in a rectangle as follows Horizontal separation between centres 145 0mm Vertical separation between centres 270 0mm The lower pair are about 10mm up from the bottom edge o...

Страница 6: ...due to differences between the individual PSTNs PABXs provided in different countries this does not of itself give an unconditional assurance of successful operation on every PSTN or PABX termination...

Страница 7: ...Tested to ETS 300 381 The GAI Tronics Quality Management System has been approved by LRQA to ISO9001 2000 Certificate No 861888 1 4 8 IEC Ex Certification Auteldac 4 complies with the following IEC st...

Страница 8: ...nsion lead The standard headset cord is approximately 820mm long and can extend to approximately 2m dependant on safe operating conditions A separate headset extension lead is available as an optional...

Страница 9: ...is connected by hard wiring unlike a normal plug and socket on internal telephones Because of this extra precautions must be observed installers must ensure that they have the permission of the owner...

Страница 10: ...telephone body must NOT be opened nor glands removed or cables disconnected unless all supplies to the telephone including telephone cables and external devices have been isolated outside the hazardou...

Страница 11: ...phone ringer can develop a sound level in excess of 90dBA 1 metre Therefore it is the installer s responsibility to take the necessary measure to comply with the European directive 2003 10 ec on the m...

Страница 12: ...llow the appropriate instructions below 2 4 Wall Mounting To ensure weatherproof integrity when wall mounted external cables should enter the enclosure from the bottom via the two 20mm gland entries p...

Страница 13: ...uare or rectangular section uprights of 100mm to 150mm across the mounting surface For flat mounting on surfaces greater than 150mm across use the desk or wall mounted methods as appropriate Figure 3...

Страница 14: ...t the unit be fixed in position using fixing positions and method detailed in section 2 4 if there is any risk of the unit being dislodged as described above To provide a rake for convenient operation...

Страница 15: ...THE CASE ALL TERMINALS MUST BE CONNECTED IN ACCORDANCE WITH THIS INSTALLATION GUIDE ANY DEVIATION FROM THIS MAY RESULT IN AN UNSAFE INSTALLATION AND VIOLATE THE CONDITIONS OF THE CERTIFICATE B A EXCH...

Страница 16: ...ction to a TELECOMMUNICATIONS NETWORK To maintain safe operation of this product the telephone line must not exceed the following Um 250V rms Rated voltage 70Vdc 100Vrms Ring Voltage Maximum power 15W...

Страница 17: ...ed such that the apparatus continues to comply with the requirements of EN 60950 2000 Typical connection scheme for a sounder and beacon Telephone connection diagram 1 2 3 4 EARTH AC NEUTRAL DC ve IN...

Страница 18: ...breaking of the relay contacts These current spikes can cause the relay contacts to fail GAI Tronics have been working closely with a leading beacon manufacturer to resolve this issue and our recommen...

Страница 19: ...CONTINUITY EARTH RING TAG CONTINUITY EARTH LOAD 1 CONNECTIONS ONLY LOAD 2 CONNECTIONS ONLY VOLT FREE CONTACT O P VOLT FREE CONTACT O P B A TE PSTN PARALLEL LINE OTHER APPROVED APPARATUS Figure 7 Wiri...

Страница 20: ...1 Dialling method Select the required dialling mode by fitting the jumper to one of the headers below as appropriate Tone dialling 87ms 87ms burst pause time HD2 Pulse dialling 10pps make break 40ms 6...

Страница 21: ...h and safety requirements regarding the exposure of workers to the risks arising from physical agents noise 2 8 4 Call Timer Fit a jumper to the ON position Figure 6 to enable the timer 6 minutes nomi...

Страница 22: ...bbon cable can lay flat and that the insulation can not become damaged IMPORTANT DAMAGED INSULATION WILL VIOLATE THE CONDITIONS OF THE CERTIFICATE Check also that the environmental seal is in position...

Страница 23: ...ncorrect wiring or cable connections Section 2 7 Improper reassembly following connection Additional holes drilled in casing 3 OPERATION Note that features may vary according to the model supplied Mem...

Страница 24: ...low cables to tangle or snare around the body or neck 3 2 Last Number Redial 15 and 18 button versions only Press LR to redial the last dialled number 3 3 Recall Function 15 and 18 button versions onl...

Страница 25: ...call turn the switch to the I position 3 To terminate the call turn the switch to the 0 position 4 To remove the headset pull the body of the connector to release the latching mechanism Do not attemp...

Страница 26: ...ning Security of the installation on wall pole or post Security and integrity of cable entries Security of the three body screws Cleanliness integrity and condition of the handset Wipe clean as necess...

Страница 27: ...Auteldac 4 26 5 CE DECLARATION...

Страница 28: ...ve any difficulties please call The policy of GAI Tronics is one of continuous improvement therefore the Company reserves the right to change specifications without notice The contents of this publica...

Отзывы: