background image

 

 

VR & Help Point 

19 

10.  Technical Specifications 

Operational Requirements 

Systems.   

 

Analogue Public Switched Telephone Network (PSTN) 

 

Private Automatic Branch Exchange (PABX) 

Not suitable for 
connection to: 

 

Payphone extensions 

 

Public Emergency Telephone System (PETS) 

Telephone line 
parameters 
(without 
supplementary 
power supply) 

 

Ring Voltage: 40V to 100V rms, 20Hz to 50Hz 

 

Line voltage 20 to 70 Vdc 

 

Loop current 

 25mA 

 

Max loop resistance 2800

 

 

Line impedance 270R + 750R||150nF as defined in ETSI 
standard ES 203 021 (previously TBR21) 

With 
supplementary 
power supply 

 

Ring Voltages down to 30V 

 

Loop current down to 15mA 

Note

: these telephones have been designed for pan-European single terminal connection 

to the PSTN. However, due to differences between the individual PSTNs & PABXs provided 
in different countries, this does not, of itself, give an unconditional assurance of successful 
operation on every PSTN or PABX termination point.

 

Product features 

Power supply 

 

Can operate from line power only. 

 

Supplementary power supply input (non-isolated) 
provided as standard.  12Vdc (±1) @ 250mA min. 

 

Supplementary power will enhance ringing and audio 
quality. 

 

Supplementary power is required for induction loop and 
external relay options. 

 

Isolated power supply input is available as an option 

 

GAI-Tronics cannot accept responsibility for the 
performance of any 3rd party supplied power supply.  If 
in doubt always use a power supply provided by GAI-
Tronics. 

Hookswitch 

Electronic with no external moving parts 

Ringer loudness 

80dBA @ 1m 

Содержание 1090

Страница 1: ...Doc No 502 20 0122 001 Iss3 Dec 2012 CN37277 002 Installation and User Guide Hands free telephones 1090 1099 models Vandal Resistant VR and Help Point GAI TRONICS...

Страница 2: ...RT features 6 5 Installation 7 5 1 General 7 5 2 Wall Pole Mounting 8 5 3 Flush mounting 11 6 Connections 12 6 1 Standard Connections 12 6 2 Supplementary Power supply 12 6 3 Optional relay outputs 13...

Страница 3: ...VR Help Point 3 8 4 Anti Graffiti Coating 18 9 Aftercare 18 10 Technical Specifications 19 11 CE Declaration 23...

Страница 4: ...elsewhere before accessing the line connections For increased protection against lightning transients attach a local earth to the main terminal block see section 6 1 2 Product Description FRONTPLATE M...

Страница 5: ...es is as follows New terminal layout section 6 Increased lightning protection section 10 Compliance with railway EMC standards section 10 Optional additional relay outputs and logic inputs section 6 3...

Страница 6: ...be able to switch into receive mode This level may vary according to ambient noise levels at the Help Point but we would recommend ensuring that the incoming signal level received at the Help point is...

Страница 7: ...es are supplied without connection leads cabling to the telephone network must be supplied and installed by the installer Because of this extra precautions must be observed installers must ensure that...

Страница 8: ...nd gland if a separate cable is required to the phone for example for an additional hook contact 2 Select the appropriate sized gland Use the smaller gland for cables diameters 4 7mm Use the larger gl...

Страница 9: ...k the wall with hole centres based on the dimensions shown 145 x 270mm If necessary offer the rear enclosure up to the wall to check alignment Do not use the enclosure as a template for drilling 3 Dri...

Страница 10: ...ar enclosure using the M6 x 25 screws provided pushing the screws through from inside the phone 3 Tighten nuts to a torque of 4 5Nm max IMPORTANT avoid the use of power tools Spinning the nuts too qui...

Страница 11: ...all to check alignment Do not use the telephone as a template for drilling 3 Drill holes in the wall at the marked positions Select appropriate screws wall plugs etc for the type of wall bearing in mi...

Страница 12: ...ided by isolation and does not rely on this earth connection Note Conductor sizes to be 0 5mm 2 5mm2 flexible cable 0 5 4 0mm2 solid cable The terminal block can be disconnected from the circuit board...

Страница 13: ...ponsibility for the performance of any 3rd party supplied power supply If in doubt always use a power supply provided by GAI Tronics 6 3 Optional relay outputs GAI Tronics hands free telephones can be...

Страница 14: ...and are not field upgradeable Contact GAI Tronics for details The inputs are provided on HD4 as shown and are also labelled on the circuit board Control inputs are for connection to voltage free conta...

Страница 15: ...2 Put the phone into maintenance mode Enter Ringing stops If you still hear ringing either the phone hasn t auto answered yet or it didn t hear the Wait a second and try again 3 Enter the access PIN...

Страница 16: ...ntering the PIN and closing the phone down with 99 ie during step 5 of the quick programming guide above To disable the timer use a value of 999 ie 50 999 The phone will respond to a successful comman...

Страница 17: ...hanging this level may cause the phone to be too loud or too quiet and in extreme cases could affect the semi duplex operation To set the phone back to its factory default volume setting use 72 26 7 3...

Страница 18: ...hemical Pay close attention to the manufacturer s recommendations for storage handling and use 8 4 Anti Graffiti Coating Where polyurethane anti graffiti coating or paint has been specified as an opti...

Страница 19: ...pan European single terminal connection to the PSTN However due to differences between the individual PSTNs PABXs provided in different countries this does not of itself give an unconditional assuranc...

Страница 20: ...m and 35dBm measured at the help point Induction loop optional Suitable for inductive coupling to Hearing Aids having a T switch position Supplementary power required Dialling and recall mode MF only...

Страница 21: ...closure See section 5 Recycling information The symbol shown here and on the product means that the product is classed as Electrical or Electronic Equipment and should not be disposed with other house...

Страница 22: ...Shock Apparatus with loudspeaking facilities for connection to U K public switched telephone networks EN50371 Generic standard to demonstrate the compliance of low power electronic and electrical app...

Страница 23: ...VR Help Point 23 11 CE Declaration...

Страница 24: ...Brunel Drive Stretton Park Burton on Trent DE13 0BZ England Tel 01283 500500 Fax 01283 500400 www gai tronics co uk The policy of GAI Tronics is one of continuous improvement therefore the Company res...