These features are all available over standard, 2 wire telephone lines with no 
external power required at the phone. 
To use these features, GAI-Tronics provide a Telephone Management 
Application (TMA) available separately, see section 7.3. 
 
 

5.  Installation 

5.1.  General  

IMPORTANT 

All possible measures must be taken to ensure water, fluid or dust 
does not contaminate the internal components of the telephone whilst 
unpacking, preparing and installing the telephone in inclement weather 
conditions or by negligence. 

Failure to do so may invalidate your warranty.

 

These telephones are supplied without connection leads – cabling to the 
telephone network must be supplied and installed by the installer. Because of 
this, extra precautions must be observed: installers must ensure that they 
have the permission of the owner of the PABX or telephone network to which 
the telephone is to be connected, and that installation is carried out by 
competent personnel. Where the telephone faceplate is mounted into an 
enclosure or recess other than the standard GAI-Tronics backbox, then 
additional care must be taken that wiring and proximity to conducting surfaces 
complies with the requirements of the R&TTE Directive - 1999/5/EC. 

Contact GAI-Tronics if installation service is required. 

From a mounting and installation point of view, VR and Help Point products 
are identical. 

Содержание 1090

Страница 1: ...Doc No 502 20 0122 001 Iss3 Dec 2012 CN37277 002 Installation and User Guide Hands free telephones 1090 1099 models Vandal Resistant VR and Help Point GAI TRONICS...

Страница 2: ...RT features 6 5 Installation 7 5 1 General 7 5 2 Wall Pole Mounting 8 5 3 Flush mounting 11 6 Connections 12 6 1 Standard Connections 12 6 2 Supplementary Power supply 12 6 3 Optional relay outputs 13...

Страница 3: ...VR Help Point 3 8 4 Anti Graffiti Coating 18 9 Aftercare 18 10 Technical Specifications 19 11 CE Declaration 23...

Страница 4: ...elsewhere before accessing the line connections For increased protection against lightning transients attach a local earth to the main terminal block see section 6 1 2 Product Description FRONTPLATE M...

Страница 5: ...es is as follows New terminal layout section 6 Increased lightning protection section 10 Compliance with railway EMC standards section 10 Optional additional relay outputs and logic inputs section 6 3...

Страница 6: ...be able to switch into receive mode This level may vary according to ambient noise levels at the Help Point but we would recommend ensuring that the incoming signal level received at the Help point is...

Страница 7: ...es are supplied without connection leads cabling to the telephone network must be supplied and installed by the installer Because of this extra precautions must be observed installers must ensure that...

Страница 8: ...nd gland if a separate cable is required to the phone for example for an additional hook contact 2 Select the appropriate sized gland Use the smaller gland for cables diameters 4 7mm Use the larger gl...

Страница 9: ...k the wall with hole centres based on the dimensions shown 145 x 270mm If necessary offer the rear enclosure up to the wall to check alignment Do not use the enclosure as a template for drilling 3 Dri...

Страница 10: ...ar enclosure using the M6 x 25 screws provided pushing the screws through from inside the phone 3 Tighten nuts to a torque of 4 5Nm max IMPORTANT avoid the use of power tools Spinning the nuts too qui...

Страница 11: ...all to check alignment Do not use the telephone as a template for drilling 3 Drill holes in the wall at the marked positions Select appropriate screws wall plugs etc for the type of wall bearing in mi...

Страница 12: ...ided by isolation and does not rely on this earth connection Note Conductor sizes to be 0 5mm 2 5mm2 flexible cable 0 5 4 0mm2 solid cable The terminal block can be disconnected from the circuit board...

Страница 13: ...ponsibility for the performance of any 3rd party supplied power supply If in doubt always use a power supply provided by GAI Tronics 6 3 Optional relay outputs GAI Tronics hands free telephones can be...

Страница 14: ...and are not field upgradeable Contact GAI Tronics for details The inputs are provided on HD4 as shown and are also labelled on the circuit board Control inputs are for connection to voltage free conta...

Страница 15: ...2 Put the phone into maintenance mode Enter Ringing stops If you still hear ringing either the phone hasn t auto answered yet or it didn t hear the Wait a second and try again 3 Enter the access PIN...

Страница 16: ...ntering the PIN and closing the phone down with 99 ie during step 5 of the quick programming guide above To disable the timer use a value of 999 ie 50 999 The phone will respond to a successful comman...

Страница 17: ...hanging this level may cause the phone to be too loud or too quiet and in extreme cases could affect the semi duplex operation To set the phone back to its factory default volume setting use 72 26 7 3...

Страница 18: ...hemical Pay close attention to the manufacturer s recommendations for storage handling and use 8 4 Anti Graffiti Coating Where polyurethane anti graffiti coating or paint has been specified as an opti...

Страница 19: ...pan European single terminal connection to the PSTN However due to differences between the individual PSTNs PABXs provided in different countries this does not of itself give an unconditional assuranc...

Страница 20: ...m and 35dBm measured at the help point Induction loop optional Suitable for inductive coupling to Hearing Aids having a T switch position Supplementary power required Dialling and recall mode MF only...

Страница 21: ...closure See section 5 Recycling information The symbol shown here and on the product means that the product is classed as Electrical or Electronic Equipment and should not be disposed with other house...

Страница 22: ...Shock Apparatus with loudspeaking facilities for connection to U K public switched telephone networks EN50371 Generic standard to demonstrate the compliance of low power electronic and electrical app...

Страница 23: ...VR Help Point 23 11 CE Declaration...

Страница 24: ...Brunel Drive Stretton Park Burton on Trent DE13 0BZ England Tel 01283 500500 Fax 01283 500400 www gai tronics co uk The policy of GAI Tronics is one of continuous improvement therefore the Company res...

Отзывы: