2.3 Operating principle
The appliance features one-hand operation. That
is to say, the ignition is activated when the control
knob is pressed briefly.
After igniting, keep the control knob pressed for
around
5-8 seconds
more because the heat sensor
that opens the gas valve has to warm up first.
The gas hob has 1
normal burner
(front burner)
and 1
high-intensity burner
(rear burner).
All burners have a
thermal protection
device that
prevents unburned gas from escaping in the open
position.
The
total rated thermal load
amounts to:
16.5 MJ (4.6 kW)
The specified rated load is defined by installation
of the fixed nozzles.
The gas hob is converted to a
different gas
type
by nozzle replacement (full and low-burning
nozzles) (see nozzle table on p. 12).
The
symbols on the control panel
mean:
0
Off
High setting
Low setting
The flame is infinitely variable between high and
low-setting.
Maintenance Instructions
– Keep appliance area clean and free from
combustible materials, gasoline and other
inflammable vapors and liquids.
– Do not obstruct the flow of combustion and
ventilation air.
– Visually check burner flames with this pictorial
representation (see figure 4).
8
Fig. 4
High
Off
Low