background image

Technical data (gas)

Burners: 
Normal burner

Full burning

6.5 MJ (1.8 kW)

Low burning

< 1.5 MJ (0.41 kW)

High-intensity burner

Full burning

10 MJ (2.8 kW)

Low burning

< 2 MJ (0.56 kW)

Gas connection:

R 1/2’’ union nut for R 1/2’’ bracket to DIN 1999,
conical-cylindrical

Technical data, gas

Technical data (electrical)

Rated consumption 

0.8 W

Voltage

220-240 V

Frequency 

50-60 Hz

Technical modifications reserved.

12

6. Technical data / Settings table

Countries

AU

AU

Gas family

Natural gas

Propane gas

Gas type

N

X

Pressure

1.0 kPa (10 mbar)

2.75 kPa (27.5 mbar)

A burner, full burning

1.18

0.74

A burner, low burning

0.58

0.36

B burner, full burning

1.48

0.87

B burner, low burning

0.68

0.42

∑ Power

16.5 MJ (4.6 kW)

16.5 MJ (4.6 kW)

∑ Consumption

0.45 m

3

/h

340 g/h

All manuals and user guides at all-guides.com

Содержание VG 232 AU

Страница 1: ...Operating principle Page 8 3 Operation Page 9 4 Cleaning and care Page 10 5 Maintenance Page 11 5 1 General Page 11 5 2 Remedying slight malfunctions yourself Page 11 6 Technical data Settings table P...

Страница 2: ...spray aerosols in the vicinity of this appliance while it is in operation WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your...

Страница 3: ...supply piping system during any pressure testing of the system at test pressures in excess of 3 5 kPa 1 2 psig The appliance must be isolated from the gas supply piping system by closing its individua...

Страница 4: ...ns conscientiously before operating it for the first time The instructions contain important notes on use installation and maintenance of the appliance You will find notes on page 5 that you ought to...

Страница 5: ...y maintenance operation To do this remove the mains plug or isolate the corresponding fuse Close the gas supply Repairs must be carried out by an authorised person No warranty claims can be lodged for...

Страница 6: ...also save gas and reduce pollution Whenever the gas hob is fitted under a vapour extractor hood always cover the rings with pots or pans Otherwise parts of the vapour extractor hood may become damage...

Страница 7: ...osition 6 Burner cover 7 Burner head 8 Spark plug for automatic ignition 9 Thermal sensor for flame monitor You can order the following special accessories VV 200 000 Connecting strip VD 201 010 Appli...

Страница 8: ...mal load amounts to 16 5 MJ 4 6 kW The specified rated load is defined by installation of the fixed nozzles The gas hob is converted to a different gas type by nozzle replacement full and low burning...

Страница 9: ...knob further to the left to the low position and then back to the high position after ignition It is often faster to ignite in the low position because the various gases have a differing ignition res...

Страница 10: ...Allow burnt in remainders to soak with a little water and detergent This loosens even the most stubborn of soiling Do not use any abrasive agents and abrasive sponges As the result of heat development...

Страница 11: ...that case call Sampford Staff Pty Ltd 421 Smith Street Fitzroy Vic 3065 Tel 03 9418 5888 Service Centres in other States Melbourne Y 03 9418 5888 Sydney Y 02 9331 8888 Adelaide Y 08 8296 0902 Brisbane...

Страница 12: ...lectrical Rated consumption 0 8 W Voltage 220 240 V Frequency 50 60 Hz Technical modifications reserved 12 6 Technical data Settings table Countries AU AU Gas family Natural gas Propane gas Gas type N...

Страница 13: ...hich this appliance is installed must have a minimum volume of 10 m3 and a door that opens out to outdoors or a window that can be opened Warning This appliance shall only be installed by an authorize...

Страница 14: ...installation of the appliance When making the connection make sure that the lead cannot come into contact with hot parts of the hob Warning This appliance is equipped with a three prong grounding plu...

Страница 15: ...ng the door of the furniture item By means of the included R 1 2 connection bracket on the appliance end with the affiliated washer the appliance must be connected to a fixed copper For Natural Gas th...

Страница 16: ...e works and so the lowest quantity is set Replacing the low setting nozzle 1 Proceed as follows Disconnect the appliance from the power supply Remove the cover from the underside of the appliance unde...

Страница 17: ...included with the nozzle set over the old adhesive label on the gas connection thus documenting the changeover to a different gas type Checking functions The flames are adjusted correctly if no yello...

Страница 18: ...th the centre marking on the worktop Fig 13 Lower the appliance into the worktop Make sure that the engaging lugs on the appliance lie exactly on the clamping springs Press the appliance firmly into t...

Страница 19: ...Operating and assembly instructions VG 232 AU Built in gas cooktop All manuals and user guides at all guides com...

Отзывы: