WARNING
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire
and the green ground wire from the oven to the neutral
electrical supply wire.
The four-wire connection is preferred, but where local
codes permit, the three wire connection is also
acceptable.
Four-wire Connection
Ungrounded Neutral
▯
Connect the red oven wire to the red electrical
supply wire (hot wire).
▯
Connect the black oven wire to the black
electrical supply wire (hot wire).
▯
Connect the white neutral oven wire to the white
neutral (not bare or green ground) electrical
supply wire.
▯
Connect the green ground oven wire to the bare
or green ground electrical supply wire.
Three-wire Connection
Grounded Neutral
▯
Connect red wire from oven to red wire in junction
box.
▯
Connect black wire from oven to black wire in
junction box.
▯
Connect both green ground wire and white wire
from oven to white, green or bare neutral wire in
junction box.
The conduit cable, where connected at the oven,
swivels.
To maintain serviceability, the flex conduit must not be
shortened and should be routed to permit temporary
removal of the oven.
Mount to Cabinet
If there is no fitted shelf above the appliance, secure
the appliance against tipping over when the door is
opened.
1
Do not kink or trap the connecting cable, or route
it over sharp edges.
2
Centre the appliance.
There must be an air gap of
3
/
16
" (5 mm) between
the appliance and adjacent cabinets.
Local codes may vary; installation, electrical
connections and grounding must comply with all
applicable local codes.