The hood can be installed in an upper cabinet
without a base. Refer to Fig. 15 for dimensions.
If no corresponding cabinet is available, remove the
base from a commercially available cabinet.
The upper cabinet must have a minimum depth of
295 mm (11 13/32") (clear width of interior) and a
minimum height of 450 mm (17 23/32").
Using the included screws, fit the retaining
brackets on the inside of the suspended cabinet
(Fig. 17). The retaining brackets must be mounted
flush with the bottom and front edges of the cabinet
at a distance of 33 mm (1 3/10”).
Using the side mounting rails, place the hood on the
pre-fitted retaining brackets and slide it towards the
rear into the cabinet (Fig. 18). The screen slide is
then flush with the bottom edge of the cabinet.
Laterally align the hood. Use the included sheet
metals screws to bolt down the retaining bracket
and the mounting rail on the left and right.
Then fit the included plastic Covers onto the
mounting rails. Use a knife to cut the plastic covers
to size if upper cabinets measure 55 cm (21 5/8”) in
width or if cabinets have a wall thickness of more
than 16 mm (5/8”).
$
CAUTION: Use care when cutting the space
rail and cover size to prevent personal injury.
Cut the included spacer rail to size so that it
bridges the distance between the rear edge of the
hood and the wall behind it.
Remove the lamp Cover (see Lamp replacement)
and bolt the spacer rail to the rear panel of the unit.
Lay the air pipes and connect the unit to the power
mains.
Fig. 17
Fig. 18
17
Содержание AH 900791
Страница 2: ...2...
Страница 15: ...15 Wire diagram AH900761 AH900791...
Страница 30: ...Sch ma de c blage 30 AH900761 AH900791...
Страница 37: ...Fig 3 Fig 4 o o o Utilizaci n 37...