42
Multi-point locks electrically couplable or with monitoring contacts
Installation instructions
SECURY 19 EK | 19 EK EVP | 19 S | 19 S EVP
04.2016 | G31347 | Designed in Germany
DE
EN
FR
ES
Scope of delivery
Multi-point lock SECURY 19 EK, 19 EK EVP, 19 S or 19 S EVP
Set with connecting cable B 5490 0300, type LiYY 14 x 0.14 mm²,
Length 10 m.
Installation and maintenance instructions M-00090-00-0
Installation instructions 0-45656-3B-0
Operating voltage *:
12-24 V DC, stabilised
Current consumption *:
max. 250 mA
Duty ratio *:
100 %
Contact load:
30 V DC / 2 A or 125 V AC / 1 A
Operating temperature:
–20°C to +60°C
Storage temperature:
–25°C to +70°C
Relative humidity:
Up to 95% at 40°C
Protection type:
IP30
Corrosion protection:
EN 1670 – Class 3
(high resistance = 96 h corrosion test)
Environment protection class:
III according to DIN EN 50131-1
(Outside – covered or inside under
extreme
environmental
conditions)
* not with SECURY 19 S / 19 S EVP
SECURY 1970 / 1970 EVP / 1971 / 1975 / 1916 S / 1916 S EVP / 1919 S
The lever handle(s) of the electrically couplable multi-point locks
is/are coupled in through a control signal.
2.5
Technical
data
2.6
Components and accessories