1.

 

PURPOSE

 

Electromechanical locks series Promix-SM213 with a locking mechanism based on a skewed 

bar (below called the locks) are intended for locking swing doors, gates and wickets located in the 
open air, which can be opened remotely by energizing/de-energizing (depending on the version) 
the  lock  with  DC  supply  voltage  by  means  of  switches  (buttons)  or  controllers  of  access 
monitoring  and  control  systems,  audio  and  video  intercoms,  code panels  or  other devices. The 
lock design and mounting method allow them to be installed on practically any door types. 

2.

 

LABELING

 

The label stuck to the lock body contains the following  
information: 

1. 

Lock model. 

2. 

Patent number. 

3. 

Nominal supply voltage. 

4. 

Nominal consumed current. 

5. 

Date of manufacture and QCD mark 

6. 

Identification number. 

7. 

Manufacturer’s website. 

 

 

For the list of lock modifications that can be ordered, see 5.2. 

 

 

3.4 

6.7 

An example of information 

layout on the label.

 

 

 

ELECTROMECHANICAL LOCK

 

Promix-SM213

 

ELECTROMECHANICAL LOCK 

 

Patent No. 2420640 
12 V=0.1 A  
Made in Russia  
No. 100 001008 

 

Supply voltage: 
0 - 12V. 1 -24V  
Version: 
0 - normally opened, 1 - normally closed 

 

engineering and production center 

Содержание Promix-SM213

Страница 1: ... audio and video intercoms code panels or other devices The lock design and mounting method allow them to be installed on practically any door types 2 LABELING The label stuck to the lock body contains the following information 1 Lock model 2 Patent number 3 Nominal supply voltage 4 Nominal consumed current 5 Date of manufacture and QCD mark 6 Identification number 7 Manufacturer s website For the...

Страница 2: ... door lock As voltage is supplied for NO lock or voltage is removed for NC lock the lock catch is block and does not permit the door opening As voltage is removed for NO lock or supplied for NC lock the lock catch is deblocked and as the door is opened is folded into the lock body 5 TECHNICAL DATA 5 1 OPERATING CONDITIONS The environment of the lock must be explosion safe free of current conductin...

Страница 3: ... of glazed frost 5 2 TECHNICAL DATA Modification Promix SM213 00 Promix SM213 01 Promix SM213 11 Promix SM213 10 Version normally opened normally closed DC supply voltage U V 12 2 24 2 12 2 Current consumed А 100 0 1 at 12V 35 at 24V 75 at 24V 160 0 1 at 12V Supply pulse duration not more than s not rated 120 at 23 26V 120 at 11 14V Minimum pause between pulses s not rated 120 Holding force not le...

Страница 4: ...door leaf During mounting a clearance of 1 8 mm must be provided between the locking plate and the fastening plate of the lock Meeting this condition guarantees a door holding force of 300 kg and a smooth operation of the door without wedging up It is necessary to provide a clearance between the catch and the locking plate in the closed state of the door Example of the lock installation in a pipe ...

Страница 5: ...Promix SM213 5 Example of the lock installation in the door frame of a wooden door Example of the lock installation in the leaf of a metal door Door Door Door Door Locking plate Locking plate ...

Страница 6: ...ition The sticker covers an opening for water drain from the lock Remove white protective film from the locking plate and the lock Example of the lock installation in the door frame of a plastic door Example of the lock installation in the leaf of a wooden door For mounting the lock drill 4 holes 2 2 5 mm in diameter for self tapping screws and the locking plate 30 32 mm in diameter for lock mount...

Страница 7: ... organization on the basis of the design features and the mounting method room criticality level the purpose of the access restriction regime and other factors the presence of security providers video surveillance etc 2 During mounting the lock and the locking plate it is necessary to ensure their coaxial alignment within the catch free movement allowance 3 NO lock may be mounted outdoors on condi...

Страница 8: ...ition If this is impossible remove the locking plate from the door Fasten the locking plate to the door providing the required clearances NC lock does not close when supply voltage is applied NO lock does not open when supply voltage is applied Check the presence of required clearances between the catch and the locking plate see section 6 9 MAINTENANCE The lock Promix SM213 is lubricated by the ma...

Страница 9: ... low DC supply voltage the products correspond to class III as per ГОСТ 12 2 007 0 75 and are electrically safe Fire safety of the locks is ensured by use of non combustible or hardly combustible materials and low supply voltage 12 DISPOSAL The product is not hazardous for human life and health or for the environment disposal after its service life is performed without taking any special measures ...

Страница 10: ...ing the manufacturing date and QCD mark on the body was manufactured and accepted in compliance with Specifications ПШБА 304268 002 ТУ obligatory requirements of state standards and current technical documentation recognized as fit for operation and packed by ETC PROMIX LLC PROMIX Engineering and Technical Center LLC Russia 214030 Smolensk Krasninskoye sh 35 lit A Phone 4812 619 330 www promix cen...

Отзывы: